BRP EVINRUDE E-TEC 200 Service Manual page 344

Table of Contents

Advertisement

TRIM AND TILT
TROUBLESHOOTING
The "B" adapter, P/N 336659, checks operation
of the DOWN circuit.
1
1. A Adapter
2. B Adapter
This kit do es no t includ e a gau ge and collar
assembly. Gauge and collar assembly shipp ed
with Power T rim/Tilt Service Kit, P/N 390 010, will
work. Gauge and Collar Assembly, P/N 983975, is
also available.
Be sure to use a fully charged battery.
STEP 1
Screw the man ual rele ase valve in the hyd raulic
unit unt il it is seate d. Place a la rge drain p an
under the unit to catch hydraulic fluid.
1
1. Manual release valve
Operate the unit to the full UP po sition, the n run
the unit down
momentarily to reduce pre ssure.
Loosen the reservoir cap one full turn. Loosen the
manual release valve three turns. Some fluid will
342
bypass the reservoir cap. These steps will relieve
the pressure in the unit.
1
2
27340
1. Manual release valve
2. Reservoir cap
Remove the manu al release valve ret aining ring
using retaining ring pliers.
Remove the manual release valve. Inst all pres-
sure gauge and a dapter "A" to check pr oblems in
the UP circuit.
IMPORTANT:
to 5 to 10 in. lbs.
torque might damage adapter or O-rings.
Cycle the unit down and up several times to purge
41736
air. With all rods fully extended, run the unit down
momentarily to reduce pressure. Che ck fluid level
again, and add flu id if nece ssary. Remember that
Torque gauge and ad apter lightly
(0.6 to 1.2 N·m). Excessive
2
41739
41754

Advertisement