Tektronix TDS3000C Series Service Manual

Digital phosphor oscilloscopes
Hide thumbs Also See for TDS3000C Series:

Advertisement

Service Manual
TDS3000C Series
Digital Phosphor Oscilloscopes
071-2507-00
This document supports firmware version 4.00
and above for TDS3000C Series instruments only.
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.

Advertisement

Table of Contents
loading

Summary of Contents for Tektronix TDS3000C Series

  • Page 1 TDS3000C Series Digital Phosphor Oscilloscopes 071-2507-00 This document supports firmware version 4.00 and above for TDS3000C Series instruments only. Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so.
  • Page 2 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material.
  • Page 3 ............5- - 1 TDS3000C Series Service Manual...
  • Page 4 ........6- - 3 TDS3000C Series Service Manual...
  • Page 5: Table Of Contents

    Table of Contents List of Figures Figure 2- -1: TDS3000C series block diagram ....2- -1 Figure 4- -1: Pulling the hub pin .
  • Page 6 ....4- -6 Table 5- -1: TDS3000C Series options ......
  • Page 7 Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product. Connect the ground lead of the probe to earth ground only. TDS3000C Series Service Manual...
  • Page 8 Terms on the Product. These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. TDS3000C Series Service Manual...
  • Page 9 Handle Components Carefully. Do not slide sensitive components over any surface. Do not touch exposed connector pins. Handle sensitive components as little as possible. Transport and Store Carefully. Transport and store sensitive components in a static-protected bag or container. TDS3000C Series Service Manual...
  • Page 10 General Safety Summary viii TDS3000C Series Service Manual...
  • Page 11 Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. TDS3000C Series Service Manual...
  • Page 12 Service Safety Summary TDS3000C Series Service Manual...
  • Page 13 Preface This Service manual provides information to troubleshoot, disassemble, and repair the following TDS3000C Series Digital Phosphor Oscilloscopes instru- ment to the module level: H TDS3012C H TDS3014C H TDS3032C H TDS3034C H TDS3052C H TDS3054C TDS3000C Series Service Manual...
  • Page 14 Preface TDS3000C Series Service Manual...
  • Page 15 H Probe compensation H Self calibration H Transporting the oscilloscope For details about operating information, see the TDS3000C Series Digital Phosphor Oscilloscope User Manual. For information about unpacking and inspecting the instrument, see Unpacking and Repacking Instructions on page 4- -39 of this manual.
  • Page 16 ( ) shows the relative charge level in the battery. The oscilloscope turns off automatically when the battery runs low. Refer to the General Safety Summary for information about proper rechargeable battery disposal. 1- 2 TDS3000C Series Service Manual...
  • Page 17 , >42 V ). To protect against this condition, attach the Tektronix-supplied grounding wire from the terminal on the rear panel to earth ground. If you use a different grounding wire, it must be larger than 18 gauge (1 mm...
  • Page 18 2. Slide the battery into the compartment and press it in from both sides until you hear the latches click. 3. Press on both sides of the battery compartment door to snap it closed. 1- 4 TDS3000C Series Service Manual...
  • Page 19 Operating Information To remove the battery, do these steps: 1. Open the battery compartment door. 2. Lift the battery handles and pull the battery out of the oscilloscope. 1- 5 TDS3000C Series Service Manual...
  • Page 20 Battery charging in oscilloscope with oscillo- 32 hours scope turned on or off Battery charging with TDS3CHG external 6 hours charger NOTE. Charge the battery before using it for the first time or after prolonged storage. 1- 6 TDS3000C Series Service Manual...
  • Page 21 Application modules Contacts Refer to the TDS3000, TDS3000B, and TDS3000C Series Application Module Installation manual that came with your application module for instructions on installing and testing an application module. NOTE. If you remove an application module, the functions provided by the application module become unavailable.
  • Page 22 3. Slide out the communication module and store it in an ESD-shielded bag. Install the blank cover if no other communication module is to be installed. Latching tab 1- 8 TDS3000C Series Service Manual...
  • Page 23 1. Push a front-panel menu button to display the menu you want to use. 2. Push a bottom screen button to select a menu item. If a pop-up menu appears, continue to push the screen button to select an item from the pop-up menu. 1- 9 TDS3000C Series Service Manual...
  • Page 24 4. Certain menu choices require you to set a numerical value to complete the setup. Use the general purpose knob to adjust the parameter value. Push the Coarse button to make larger adjustments. 1- 10 TDS3000C Series Service Manual...
  • Page 25 4. Display. Changes the appearance of waveforms and the display screen. 5. QuickMenu. Activates QuickMenus such as the built-in Scope QuickMenu. 6. Utility. Activates the system utility functions, such as selecting a language. 1- 11 TDS3000C Series Service Manual...
  • Page 26 4. Vertical Position. Adjusts the vertical position of the selected waveform. Push Coarse to make adjustments more quickly. 5. Horizontal Position. Adjusts the trigger point location relative to the acquired waveforms. Push Coarse to make adjustments quickly. 1- 12 TDS3000C Series Service Manual...
  • Page 27 17. Waveform Off. Removes the selected waveform from the display. 18. Vertical Scale. Adjusts the vertical scale factor of the selected waveform. 19. CH1, CH2, (CH3, CH4,) Math. Displays a waveform and chooses the selected waveform. Ref shows the reference waveform menu. 1- 13 TDS3000C Series Service Manual...
  • Page 28 21. Power. Turns power to on or standby. 22. Wrist-strap ground. Use to connect a wrist strap when working with ESD-sensitive circuits. This connector is not a safety ground. 23. Menu Off. Clears menu from the display. 1- 14 TDS3000C Series Service Manual...
  • Page 29 9. Trigger readouts show the trigger sources, slopes, and levels, and position. 10. Readout shows the delay setting or the trigger location within the record. 11. Horizontal readout shows the main or zoom time/division. 1- 15 TDS3000C Series Service Manual...
  • Page 30 For example, if you want to add an automatic measurement, push the Meas button to set up the measurement. Then, push the QuickMenu button to return to the Scope QuickMenu with the measurement also in the display. 1- 16 TDS3000C Series Service Manual...
  • Page 31 Those items are described on page 1- -15. Other QuickMenus. Some optional application packages include a custom QuickMenu display. Those QuickMenus contain specific features that are important for the application. 1- 17 TDS3000C Series Service Manual...
  • Page 32 2. CH1, CH 2, (CH3, CH4). Channel inputs with TekProbe interface. 3. EXT TRIG. External trigger input with TekProbe interface (two-channel models only). Four-channel models have an external trigger input on the rear of the oscilloscope. 1- 18 TDS3000C Series Service Manual...
  • Page 33 5. Ground terminal. Connect to earth ground when using battery power. See page 1- -3 for important safety information. 6. CAL switch. For use by authorized service personnel only. 1- 19 TDS3000C Series Service Manual...
  • Page 34 1. GPIB port. Connect to a controller for remote programmability. 2. RS-232 port. Connect to a controller or terminal for remote programmability or printing. 3. VGA port. Connect to a VGA monitor to display the screen image. 1- 20 TDS3000C Series Service Manual...
  • Page 35 CH 1 2. Check the shape of the displayed waveform. Overcompensated Undercompensated Compensated correctly 3. If necessary, adjust your probe. P3010 P6139A Repeat as necessary. 1- 21 TDS3000C Series Service Manual...
  • Page 36 3. Push the System screen button to select Cal. 4. Push the Signal Path screen button. 5. Push OK Compensate Signal Path. This procedure takes several minutes to complete. NOTE. The signal path compensation does not include calibration to the probe tip. 1- 22 TDS3000C Series Service Manual...
  • Page 37 Use the supplied cord retainer if the power plug does not have a molded-in retainer. The oscilloscope front cover has a convenient place to store TDS3000C Series 1/4-size user and reference manuals. If you are not using a battery, you can use the accessory tray in the battery compartment to store probes and other accessories.
  • Page 38 Operating Information 1- 24 TDS3000C Series Service Manual...
  • Page 39: Figure 2- 1: Tds3000C Series Block Diagram

    Ch 1 Ch 2 2-channel oscilloscopes Figure 2- 1: TDS3000C series block diagram Power Supply The power supply converts AC line voltage to 15 VDC to power all internal circuits. It also supplies power to charge the optional battery pack.
  • Page 40 Display System The display system combines live waveform data from acquisition memory with menus and text and stores this information in display memory. It then uses this data to refresh the VGA display module (LCD). 2- 2 TDS3000C Series Service Manual...
  • Page 41 The front-panel board also generates the probe compensation output signal and provides an interface to the application modules. USB Port The front panel USB Flash Drive port is a host port. This port is only for use with a USB flash drive. 2- 3 TDS3000C Series Service Manual...
  • Page 42 Theory of Operation 2- 4 TDS3000C Series Service Manual...
  • Page 43 Adjustment Procedures This chapter contains the factory adjustment procedures for the TDS3000C series oscilloscopes. Only qualified personnel should perform adjustment procedures. Read the Service Safety Summary and the General Safety Summary before performing any service procedures. Also refer to the chapter Operating Information for information about using the oscilloscope.
  • Page 44 If all steps in the procedure are completed successfully, a “Pass” message is displayed and the new calibration constants take affect. If the procedure fails for any reason, the oscilloscope reverts to the previous calibration settings. 3- 2 TDS3000C Series Service Manual...
  • Page 45 DC voltage to the specified value. DC voltage Four-channel oscilloscope source Equal-length BNC cables BNC tees DC voltage Two-channel oscilloscope source Equal-length BNC cables BNC tee 3- 3 TDS3000C Series Service Manual...
  • Page 46 NOTE. If the leveled sine wave generator you are using has an output head, connect the head directly to the channel input. Make sure that the AC generator output is set for a 50-ohm load for all AC-source steps. 3- 4 TDS3000C Series Service Manual...
  • Page 47 DC voltage to the specified value. DC voltage source Oscilloscope Ext Trig NOTE. If the DC voltage source you are using has an output head, connect the head directly to the external trigger input. 3- 5 TDS3000C Series Service Manual...
  • Page 48 NOTE. Do not skip the Recall Factory Setup steps. You must recall the factory settings in order to correctly start the factory adjustment procedure. 7. Push the MENU OFF button. 3- 6 TDS3000C Series Service Manual...
  • Page 49 14. Do the performance verification tests (found in the Specifications and Performance Verification technical reference, available on the Web at www.tektronix.com/manuals) to verify that the adjustment procedure has correctly calibrated the oscilloscope. Incorrect use of calibration equipment can cause the oscilloscope to pass the adjustment procedure but fail performance verification.
  • Page 50 Adjustment Procedures 3- 8 TDS3000C Series Service Manual...
  • Page 51 CAUTION. Static discharge can damage any semiconductor component in this instrument. 1. Minimize handling of static-sensitive modules. 2. Transport and store static-sensitive modules in their static protected containers or on a metal rail. Label any package that contains static-sensitive modules. 4- 1 TDS3000C Series Service Manual...
  • Page 52 Dirt acts as an insulating blanket, preventing efficient heat dissipa- tion. Dirt also provides an electrical conduction path that could cause an oscilloscope failure, especially under high-humidity conditions. 4- 2 TDS3000C Series Service Manual...
  • Page 53 Metal chassis pieces Bent, fractured, or broken pieces. Repair or replace defective hard- ware. Circuit boards Loose, broken, or corroded solder Remove failed module and replace connections. Burned circuit with a new module. boards. Burned, broken, or cracked circuit-run plating. 4- 3 TDS3000C Series Service Manual...
  • Page 54 6. Dry all components and assemblies in an oven or drying compartment using low-temperature (52_ C to 66_ C / 125_ F to 150_ F) circulating air. Lubrication. There is no periodic lubrication required for the oscilloscope. 4- 4 TDS3000C Series Service Manual...
  • Page 55 List of Modules The Mechanical Parts List chapter provides a list of all replaceable modules. Any electrical or mechanical module, assembly, or part listed in the parts list is referred to as a module. 4- 5 TDS3000C Series Service Manual...
  • Page 56 Display module Front-panel USB port Inverter cable Inverter board Display module Display Inverter board Inverter board NO TAG and backlights Backlight tubes Front panel Knobs 4- - 30 Front-panel board Flex circuit keypad contacts Keypads 4- 6 TDS3000C Series Service Manual...
  • Page 57 T-15 tips (If you are using a magnetic screwdriver with interchangeable bits, the T-15 bit must be a long bit, at least 5 cm. (2 in) overall length). H Screwdriver with inch flat blade H Needle-nose pliers 4- 7 TDS3000C Series Service Manual...
  • Page 58 6 mm (0.25 in). If you accidentally pull the metal pin all the way out, reinsert it half way. The pin may be positioned at either the top or bottom of the hub assembly. 4- 8 TDS3000C Series Service Manual...
  • Page 59: Figure 4- 1: Pulling The Hub Pin

    7. Pull outward on the handle at the hub to release the display-side hub assembly. You may need to rotate the handle up and down slightly to help release the hub assembly. See Figure 4- -2. 4- 9 TDS3000C Series Service Manual...
  • Page 60: Figure 4- 2: Releasing The Hub Assembly

    If the hub does not rotate with the handle, return the handle to the down position, pull the pin out a little farther, and then rotate the handle toward the top of the oscilloscope. 4- 10 TDS3000C Series Service Manual...
  • Page 61 2. Verify that the front and rear cases fit together tightly. 3. Grasp the handle from both sides and stretch it over the over the top of the oscilloscope. Rotate the handle into its full upright position. The Tektronix logo should appear right-side up when looking down on the handle.
  • Page 62: Figure 4- 3: Reinstalling A Hub Cover

    1. Place the oscilloscope face down on soft surface (such as an anti-static mat), with the bottom facing you. 2. Remove the T-15 TORX screw just above the power plug. 3. Remove the communication module cover or any communication module that may be installed. 4- 12 TDS3000C Series Service Manual...
  • Page 63: Figure 4- 4: Communication Module Guide

    Installation. Use this procedure to install the communication module guide, feet, rear case, and communication module cover. 1. Place the oscilloscope face down on soft surface (such as an anti-static mat), with the bottom facing you. 4- 13 TDS3000C Series Service Manual...
  • Page 64 3. Turn the oscilloscope around so the top is facing you, and disconnect the following cables (see Figure 4- -5): a. Rear USB cable from main board connector J815. b. Ethernet cable from main board connector J920. 4- 14 TDS3000C Series Service Manual...
  • Page 65: Figure 4- 5: Rear Chassis Cables To The Main Board

    6. Unplug the braided cable from the rear chassis BNC connector (four-channel models only). Note how the cable is routed for when you reassemble the instrument. Figure 4- 5: Rear chassis cables to the main board 4- 15 TDS3000C Series Service Manual...
  • Page 66 3. If you are replacing the power supply board, remove the two screws that secure the power supply to the power supply bracket, and install the bracket on the new power supply board. 4- 16 TDS3000C Series Service Manual...
  • Page 67: Figure 4- 6: Installing The Fan, Line Filter, And Line Power Cable

    The fan label should face toward the rear chassis. See Figure 4- -6. Label Fan cable hole Rear chassis Bend the tabs Figure 4- 6: Installing the fan, line filter, and line power cable 4- 17 TDS3000C Series Service Manual...
  • Page 68: Figure 4- 7: Installing The Ac Line Filter And Shield

    Secure the AC shield/filter assembly with two screws. See Figure 4- -7. Line power conductor AC Filter shield Line filter Power supply board Figure 4- 7: Installing the AC line filter and shield 4- 18 TDS3000C Series Service Manual...
  • Page 69: Figure 4- 8: Installing The Line Filter And Line Power Cable

    7. Attach the DC power cable to the power supply. 8. Connect the fan power cable to the battery board at J170. 9. Connect the DC power cable to the battery board at J180. 4- 19 TDS3000C Series Service Manual...
  • Page 70 20. Turn the oscilloscope around so the top is facing you, and connect the following cables (see Figure 4- -5): a. Rear USB cable to main board connector J815 b. Ethernet cable to main board connector J920 4- 20 TDS3000C Series Service Manual...
  • Page 71 6. Release the two snaps that hold the main board (see Figure 4- -9). Lift the main board out of the front-panel assembly. 7. Use the inch flat-bladed screwdriver to carefully lift the display cable from connector J500 on the main board. See Figure 4- -9. 4- 21 TDS3000C Series Service Manual...
  • Page 72: Figure 4- 9: Main Board

    H Do not apply any sideways force on the pogo pins, or slide any objects across the pogo pins, as they are easily bent H If replacing the main board, place the old main board on the main board foam carrier that came with the new main board 4- 22 TDS3000C Series Service Manual...
  • Page 73 CAUTION. Make sure that the lower legs of the connector clip are not in contact with any components on the bottom of the circuit board. Board damage may result. 5. Push down on the two main board corners to engage the snaps. 4- 23 TDS3000C Series Service Manual...
  • Page 74: Figure 4- 10: Install The J500 Connector Clip

    10. On four-channel models, use Kapton tape to secure the trigger cable to the side of the chassis. Arrange the cable for the most clearance between the trigger cable and the display cable. 4- 24 TDS3000C Series Service Manual...
  • Page 75: Figure 4- 11: Taping Trigger Cable (Four-Channel Models Only) And Display Cable

    Maintenance Figure 4- 11: Taping trigger cable (four-channel models only) and display cable 4- 25 TDS3000C Series Service Manual...
  • Page 76: Figure 4- 12: Front Chassis

    4. Place the front chassis with the display facing you. See Figure 4- -13. 5. Use your thumbs to slide the top display module tabs up until the overhang- ing part of the tabs clear the chassis holes. See Figure 4- -13. 4- 26 TDS3000C Series Service Manual...
  • Page 77: Figure 4- 13: Display Module

    3. Use your thumbs to slide all four display module tabs down as far as possible to lock the display module in place on the front chassis. 4. Place the oscilloscope face down on a soft surface (such as an anti-static mat), with the bottom facing you. 4- 27 TDS3000C Series Service Manual...
  • Page 78: Figure 4- 14: Front-Panel Cable Routing

    8. Route the front-panel cable through the notch located on the bottom edge of the front chassis. See Figure 4- -14. 9. Use the TORX T-10 screwdriver to insert the two screws that secure the front chassis to the front case. 4- 28 TDS3000C Series Service Manual...
  • Page 79: Figure 4- 15: Front-Panel Usb Port Removal

    3. Insert the USB connector into the front chassis. The connector will only fit into the chassis cutout when it is in the correct orientation. Push the connector in until it snaps into place. 4- 29 TDS3000C Series Service Manual...
  • Page 80 2. Remove the front-panel knobs by firmly pulling each knob away from the front panel. Careful prying with a small screwdriver or similar tool may be be necessary. See Figure 4- -16. Remove knobs (7) Figure 4- 16: Remove front-panel knobs 4- 30 TDS3000C Series Service Manual...
  • Page 81 Figure 4- -17. Board snap (6) Board snap (5) Board snap (4) Board snap (2) Board snap (3) Board snap (1) Lift board from this corner Figure 4- 17: Remove front-panel board 4- 31 TDS3000C Series Service Manual...
  • Page 82 6. Remove the front-panel and bezel button keypads by lifting them away from the front panel. Do not touch the keypad contacts or place them on a contaminated surface. See Figure 4- -18. Front panel keypad Bezel keypad Figure 4- 18: Remove front-panel keypads 4- 32 TDS3000C Series Service Manual...
  • Page 83 6. Route the front-panel cable as described in steps 5 and 6 on page 4- -28. 7. Install the front-panel knobs by firmly pushing each knob onto the front panel knob shaft. Align the flat side of the knob shaft with the flat part of the knob hole. 4- 33 TDS3000C Series Service Manual...
  • Page 84 Maintenance 4- 34 TDS3000C Series Service Manual...
  • Page 85 Troubleshooting This section contains information and procedures to help you isolate a defective module in a TDS3000C series oscilloscope. WARNING. Before doing this or any other procedure in this manual, read the General Safety Summary and Service Safety Summary found at the beginning of this manual.
  • Page 86: Figure 4- 20: Primary Troubleshooting Procedure

    (Figure 4- - 21). Does Perform the Module Isolation the scope pass all the troubleshooting procedure diagnostics? (Figure 4- - 22). Done. Figure 4- 20: Primary troubleshooting procedure 4- 36 TDS3000C Series Service Manual...
  • Page 87: Figure 4- 21: Ac Power Supply Troubleshooting Procedure

    +15 volts between pins Power Supply module. 1 and 6? AC power supply OK. Return the TDS3000C oscilloscope to the nearest Tektronix Service Center for repair. Figure 4- 21: AC power supply troubleshooting procedure 4- 37 TDS3000C Series Service Manual...
  • Page 88: Figure 4- 22: Module Isolation Troubleshooting Procedure

    Main board Main board Display Main board Front Panel Front Panel (or Main board) Comm module (or Main board) Main board App Modules Front Panel (or App keys) Figure 4- 22: Module isolation troubleshooting procedure 4- 38 TDS3000C Series Service Manual...
  • Page 89 Use a corrugated cardboard shipping carton having a test strength of at least 275 pounds (125 kg) and with an inside dimension at least six inches (15.25 cm.) greater than the instrument dimensions. If the instrument is being shipped to a Tektronix Service Center, enclose the following information: H The owner’s address...
  • Page 90 Maintenance 4- 40 TDS3000C Series Service Manual...
  • Page 91 Options The TDS3000C series options, listed in Table 5- -1, provide power cords and documentation packages for international customers. Table 5- 1: TDS3000C Series options Option Description North America power Universal EURO power United Kingdom power Australia power Switzerland power...
  • Page 92 Options 5- 2 TDS3000C Series Service Manual...
  • Page 93 670-7918-03 670-7918-XX When you order parts, Tektronix will provide you with the most current part for your product type, serial number, and modification (if applicable). At the time of your order, Tektronix will determine the part number revision level needed for your product, based on the information you provide.
  • Page 94 Module Servicing Modules can be serviced by selecting one of the following three options. Contact your local Tektronix service center or representative for repair assistance. Module Exchange. In some cases you may exchange your module for a reman- ufactured module. These modules cost significantly less than new modules and meet the same factory specifications.
  • Page 95 Items in this section are referenced by figure and index numbers to the exploded view illustrations that precede the list Tektronix part number Use this part number when ordering replacement parts from Tektronix 3 and 4 Serial number Column three indicates the serial number at which the part was first effective. Column four indicates the serial number at which the part was discontinued.
  • Page 96: Figure 6- 1: Exploded View, Front Case Half

    Replaceable Parts List Figure 6- 1: Exploded view, front case half 6- 4 TDS3000C Series Service Manual...
  • Page 97 200- - 4416- - 01 COVER:FRONT,PROTECTIVE,13.850 X 7.090 X 2.050,PC/ABS,FR110,BLUE 366- - 0772- - 00 KNOB,CAP:PC/ABS BAYBLEND FR110,SIVER GRAY,0.425 DIA X 0.520 H 366- - 0771- - 00 KNOB,CAP:PC/ABS BAYBLEND FR110,SILVER GRAY,0.650 DIA X 0.520 H 6- 5 TDS3000C Series Service Manual...
  • Page 98: Figure 6- 2: Exploded View, Lcd Display

    Replaceable Parts List Figure 6- 2: Exploded view, LCD display 6- 6 TDS3000C Series Service Manual...
  • Page 99 Exploded view, LCD display 441- - 2506- - 00 CHASSIS:FRONT,0.050 AL,13.020 X 2.860 650- - 5119- - 00 LCD MODULE ASSY; TDS3000C SERIES 211- - 0927- - 00 SCREW,PT:K35- - 1.57 X 10.0MM,T10,STL,BLACK 174- - 5411- - 00 CABLE EXTENSION, USB- - HOST 131- - 6521- - 00 CONTACT,ELEC:EMI,CLIP- - ON,0.38 L X 0.500 W (2 CONTACTS) X 0.45 HIGH,ELECTROLESS...
  • Page 100: Figure 6- 3: Exploded View, Main Board

    Replaceable Parts List Figure 6- 3: Exploded view, main board 6- 8 TDS3000C Series Service Manual...
  • Page 101 CIRCUIT BD ASSY; MAIN, 4 CH, 500 MHZ, (TDS3054C ONLY) 211- - 0721- - 00 SCREW,MACHINE:6- - 32 X 0.375,PNH,STL,CDPL,T- - 15 TORX DR 351- - 1025- - 00 GUIDE:OPTION MODULE,POLY,ABS ALLY,BAYBLEND FR- - 110 6- 9 TDS3000C Series Service Manual...
  • Page 102: Figure 6- 4: Exploded View, Circuit Board Assembly And Fan

    Replaceable Parts List Figure 6- 4: Exploded view, circuit board assembly and fan 6- 10 TDS3000C Series Service Manual...
  • Page 103 CABLE ASSEMBLY (2 X 13 POWER) 174- - 3767- - 01 CA ASSY, SP; DISCRETE, BACKLIGHT, IDC 260- - 2443- - 00 SWITCH,PWR:DPDT,PUSH PUSH ALT ACT,PC PINS 384- - 1813- - 00 SHAFT:BAYBLEND FR110,SILVER GREY 6- 11 TDS3000C Series Service Manual...
  • Page 104: Figure 6- 5: Exploded View, Rear Case Half

    Replaceable Parts List Figure 6- 5: Exploded view, rear case half 6- 12 TDS3000C Series Service Manual...
  • Page 105 202- - 0455- - 00 CASE ASSEMBLY; CASE, W/REAR DOOR, REAR FOOT & CUSHION;TDS3000C, SAFETY CONTROLLED 348- - 1582- - 00 FOOT ASSY:FRONT,HINGED,HOUSING 380- - 1118- - 00, FRONT FOOT 348- - 1557- - 00, 6- 13 TDS3000C Series Service Manual...
  • Page 106 TDS3CHG EXTERNAL BATTERY CHARGER _________ TDS3BATC RECHARGEABLE BATTERY PACK _________ AC3000 OSC SOFT CARRY CASE _________ RM3000 RACK MOUNT KIT _________ NI LabVIEW SignalExpress Tektronix Edition software for OSC _________ OpenChoiceR Desktop PC Communications software for OSC 6- 14 TDS3000C Series Service Manual...

This manual is also suitable for:

Tds3012cTds3014cTds3032cTds3034cTds3052cTds3054c

Table of Contents