WARNING
!
Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance.
The vent system must be supported every 3'(0.9m) for both vertical and horizontal runs. Use support ring assembly W010-
0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and
horizontal runs. Spacers are attached to the inner pipe at predetermined intervals to maintain an even air gap to the outer
WARNING
pipe. This gap is required for safe operation. A spacer is required at the start, middle, and end of each elbow to ensure this
!
gap is maintained. These spaces must not be removed.
WARNING
!
WARNING
!
Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance.
This appliance uses a 4" (102mm) exhaust / 7" (178mm) air intake vent pipe system. Refer to the section applicable
The vent system must be supported every 3'(0.9m) for both vertical and horizontal runs. Use support ring assembly W010-
Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance.
to your installation.
Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance.
0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and
The vent system must be supported every 3'(0.9m) for both vertical and horizontal runs. Use support ring assembly W010-
The vent system must be supported every 3'(0.9m) for both vertical and horizontal runs. Use support ring assembly W010-
For safe and proper operation of the appliance, follow the venting instructions exactly. Deviation from the minimum vertical
horizontal runs. Spacers are attached to the inner pipe at predetermined intervals to maintain an even air gap to the outer
0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and
0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and
vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes
pipe. This gap is required for safe operation. A spacer is required at the start, middle, and end of each elbow to ensure this
horizontal runs. Spacers are attached to the inner pipe at predetermined intervals to maintain an even air gap to the outer
horizontal runs. Spacers are attached to the inner pipe at predetermined intervals to maintain an even air gap to the outer
(5-15) for the fl ame to stabilize after ignition. Although not a requirement, it is recommended for vent lengths that pass through
gap is maintained. These spaces must not be removed.
pipe. This gap is required for safe operation. A spacer is required at the start, middle, and end of each elbow to ensure this
pipe. This gap is required for safe operation. A spacer is required at the start, middle, and end of each elbow to ensure this
unheated spaces (attics, garages, crawl spaces) be insulated with the insulation wrapped in a protective sleeve to minimize
gap is maintained. These spaces must not be removed.
gap is maintained. These spaces must not be removed.
condensation. Provide a means for visually checking the vent connection to the appliance after the appliance is installed. Use a
This appliance uses a 4" (102mm) exhaust / 7" (178mm) air intake vent pipe system. Refer to the section applicable
fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.
to your installation.
This appliance uses a 4" (102mm) exhaust / 7" (178mm) air intake vent pipe system. Refer to the section applicable
This appliance uses a 4" (102mm) exhaust / 7" (178mm) air intake vent pipe system. Refer to the section applicable
to your installation.
For safe and proper operation of the appliance, follow the venting instructions exactly. Deviation from the minimum vertical
to your installation.
The vent terminal may be painted with a high temperature paint to match exterior colours. Use an outdoor paint suitable for
vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes
For safe and proper operation of the appliance, follow the venting instructions exactly. Deviation from the minimum vertical
400°F (200°C). Application and performance of paint is the consumer's responsibility. Spot testing is recommended.
For safe and proper operation of the appliance, follow the venting instructions exactly. Deviation from the minimum vertical
(5-15) for the fl ame to stabilize after ignition. Although not a requirement, it is recommended for vent lengths that pass through
vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes
vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes
note:
unheated spaces (attics, garages, crawl spaces) be insulated with the insulation wrapped in a protective sleeve to minimize
(5-15) for the fl ame to stabilize after ignition. Although not a requirement, it is recommended for vent lengths that pass through
(5-15) for the fl ame to stabilize after ignition. Although not a requirement, it is recommended for vent lengths that pass through
If for any reason the vent air intake system is disassembled, re-install per the instructions provided for the initial installation.
condensation. Provide a means for visually checking the vent connection to the appliance after the appliance is installed. Use a
unheated spaces (attics, garages, crawl spaces) be insulated with the insulation wrapped in a protective sleeve to minimize
unheated spaces (attics, garages, crawl spaces) be insulated with the insulation wrapped in a protective sleeve to minimize
condensation. Provide a means for visually checking the vent connection to the appliance after the appliance is installed. Use a
fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.
This appliance must be installed with a continuous connection of exhaust and air intake vent pipes. Utilizing alternate
condensation. Provide a means for visually checking the vent connection to the appliance after the appliance is installed. Use a
fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.
constructions such as a chimney as part of the vent system is not permitted.
fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.
The vent terminal may be painted with a high temperature paint to match exterior colours. Use an outdoor paint suitable for
400°F (200°C). Application and performance of paint is the consumer's responsibility. Spot testing is recommended.
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components.
The vent terminal may be painted with a high temperature paint to match exterior colours. Use an outdoor paint suitable for
The vent terminal may be painted with a high temperature paint to match exterior colours. Use an outdoor paint suitable for
400°F (200°C). Application and performance of paint is the consumer's responsibility. Spot testing is recommended.
Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent pipes to combustibles
two single family dwellings and serves both dwellings. Local codes or regulations may require different
400°F (200°C). Application and performance of paint is the consumer's responsibility. Spot testing is recommended.
note:
and air terminal locations as set out in this manual apply to all vent systems and must be adhered to. For Simpson Dura-Vent,
clearances.
note:
If for any reason the vent air intake system is disassembled, re-install per the instructions provided for the initial installation.
note:
Selkirk Direct Temp, American Metal Amerivent and Metal-Fab, follow the installation procedure provided with the venting
If for any reason the vent air intake system is disassembled, re-install per the instructions provided for the initial installation.
Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows. Keep it pulled
If for any reason the vent air intake system is disassembled, re-install per the instructions provided for the initial installation.
components or on the website for your venting supplier.
This appliance must be installed with a continuous connection of exhaust and air intake vent pipes. Utilizing alternate
tight. A 1-1/4" (25.4mm - 6.4mm) air gap all around between the inner liner and outer appliance pipe is
A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:
constructions such as a chimney as part of the vent system is not permitted.
This appliance must be installed with a continuous connection of exhaust and air intake vent pipes. Utilizing alternate
This appliance must be installed with a continuous connection of exhaust and air intake vent pipes. Utilizing alternate
required for safe operation. Use a firestop when penetrating interior walls, floor or ceiling.
constructions such as a chimney as part of the vent system is not permitted.
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components.
constructions such as a chimney as part of the vent system is not permitted.

Venting

Starter Adapter Part Number Supplier
Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent pipes to combustibles
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components.
Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components.
System
and air terminal locations as set out in this manual apply to all vent systems and must be adhered to. For Simpson Dura-Vent,
Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent pipes to combustibles
Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent pipes to combustibles
Selkirk Direct Temp, American Metal Amerivent and Metal-Fab, follow the installation procedure provided with the venting
and air terminal locations as set out in this manual apply to all vent systems and must be adhered to. For Simpson Dura-Vent,
Duravent
W175-0053
and air terminal locations as set out in this manual apply to all vent systems and must be adhered to. For Simpson Dura-Vent,
components or on the website for your venting supplier.
Selkirk Direct Temp, American Metal Amerivent and Metal-Fab, follow the installation procedure provided with the venting
Selkirk Direct Temp, American Metal Amerivent and Metal-Fab, follow the installation procedure provided with the venting
Amerivent
4DSC-N2
A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:
components or on the website for your venting supplier.
components or on the website for your venting supplier.
A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:
A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier:
Direct Temp
4DT-AAN
Venting
Starter Adapter Part Number Supplier
System
Venting
SureSeal
4DNA
Venting
Vent
Starter Adapter Part Number Supplier
Starter Adapter Part Number Supplier
Starter Adapter Part Number Supplier
System
Manufacturer
System
Duravent
W175-0053
For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high
Duravent
W175-0053
temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all
Duravent
Duravent
GDS924N
W175-0053
Amerivent
4DSC-N2
other approved vent systems except for the exhaust vent pipe connection to the appliance fl ue collar which must be sealed
Amerivent
4DSC-N2
Amerivent
Amerivent
4DSC-N2
4DSC-N2
using the black high temperature sealant Mill Pac. High temperature sealant must be ordered separately.
Direct Temp
4DT-AAN
Direct Temp
4DT-AAN
Direct Temp
Direct Temp
4DT-AAN
4DT-AAN
SureSeal
4DNA
SureSeal
This template must be used in conjunction with templates 7.1.1 or 7.1.2, depending on
4DNA
SureSeal
4DNA
SuperSeal
4DNA
For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high
termination shape (i.e. round, or round and square). See appropriate templates folder.
temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all
For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high
For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high
other approved vent systems except for the exhaust vent pipe connection to the appliance fl ue collar which must be sealed
temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all
temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all
using the black high temperature sealant Mill Pac. High temperature sealant must be ordered separately.
other approved vent systems except for the exhaust vent pipe connection to the appliance fl ue collar which must be sealed
For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum.
other approved vent systems except for the exhaust vent pipe connection to the appliance fl ue collar which must be sealed
using the black high temperature sealant Mill Pac. High temperature sealant must be ordered separately.
using the black high temperature sealant Mill Pac. High temperature sealant must be ordered separately.
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that
When using Wolf Steel venting components, use only approved Wolf Steel termination kits: wall terminal kit GD-
This template must be used in conjunction with templates 7.1.1 or 7.1.2, depending on
it is unobstructed and undamaged.
175 (7/12" of venting included), or 1/12 to 7/12 pitch roof terminal kit GD-110, 8/12 to 12/12 roof terminal kit GD-
This template must be used in conjunction with templates 7.1.1 or 7.1.2, depending on
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not
termination shape (i.e. round, or round and square). See appropriate templates folder.
This template must be used in conjunction with templates 7.1.1 or 7.1.2, depending on
111, flat roof terminal kit GD-112, or periscope kit GD-180 (for wall penetration below grade) in conjunction with
be combined.
termination shape (i.e. round, or round and square). See appropriate templates folder.
the appropriate venting components.
termination shape (i.e. round, or round and square). See appropriate templates folder.
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20
For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum.
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two
For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum.
horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.
For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum.
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that
it is unobstructed and undamaged.
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that
Horizontal runs may have a 0" rise per foot or 0mm rise per meter however for optimum performance it is recommended
The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that
it is unobstructed and undamaged.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not
that all horizontal runs have a minimum 1/4" rise per foot or 21mm rise per meter using fl exible venting. For safe and proper
it is unobstructed and undamaged.
be combined.
operation of the appliance, follow the venting instructions exactly.
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not
Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not
be combined.
be combined.
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20
A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two
and serves both dwellings. Local codes or regulations may require different clearances.
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20
These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20
horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two
Website
Wolf Steel
www.duravent.com
American Metal
www.americanmetalproducts.com
Selkirk
www.selkirkcorp.com
Website
Metal-Fab
www.mtlfab.com
Website
Website
Website
Wolf Steel
www.duravent.com
Wolf Steel
www.duravent.com
Wolf Steel
Wolf Steel
www.duravent.com
www.duravent.com
American Metal
www.americanmetalproducts.com
American Metal
www.americanmetalproducts.com
American Metal
American Metal
www.americanmetalproducts.com
www.americanmetalproducts.com
Selkirk
www.selkirkcorp.com
Selkirk
www.selkirkcorp.com
Selkirk
Selkirk
www.selkirkcorp.com
www.selkirkcorp.com
Metal-Fab
www.mtlfab.com
Metal-Fab
www.mtlfab.com
Metal-Fab
www.mtlfab.com
Metal-Fab
www.mtlfab.com
2.0 venting
EN
9
W415-4005 / A / 07.22.21

Advertisement

Table of Contents
loading

Table of Contents