Lcd Display Messages - Raynor ControlHoist 2.0 Standard Installation Instructions And User Manual

Hide thumbs Also See for ControlHoist 2.0 Standard:
Table of Contents

Advertisement

D
s i
p
a l
y
"Locked Out"
"TCS Paused"
"Lock Bar Detected"
"Close in XX sec."
"Sensor 1 activated"
"Sensor 2 activated"
"Aux 1 activated"
"Aux 2 activated"
"At Open Limit"
"At Close Limit"
"Aux Board Connected"
"Partially Open"
"Opening Door Running" This message will display when the door is running in the open direction.
"Closing Door Running" This message will display when the door is running in the closed direction.
5793130-14

LCD DISPLAY MESSAGES

The LCD display will read "locked Out" when either the on board chain hoist interlock, or
the door interlock, on terminal block 2 is activated. These connections will have a jumper
when not required.
When in Timer to close mode (TCS), and door is in the open position, if the stop button
is pressed while timer is still counting down it will pause the timer until either the open or
close button is pressed.
This message will display whenever the open button is pressed and the limit nut does
NOT come off the close limit switch with in a certain amount of time. If the door is stuck
down for any reason, the open cycle will shut down to save damage to the door.
When in timer to close mode, and the door is in the open position, the display will read
the amount of time in seconds that is remaining until door closes. You can activate the
stop button to pause this countdown.
This message will display anytime the board is not receiving a signal from the sensor 1,
when close button is pressed. Whether it is not connected, activated, or has
malfunctioned.
This message will display anytime the board is not receiving a signal from the sensor 2,
when close button is pressed. Whether it is not connected, activated, or has
malfunctioned. If no sensor is required on sensor 2, select "None Connected" in the
program.
This message will display anytime the board is not receiving a signal from the Aux 1
when close button is pressed. Whether it is not connected, activated, or has
malfunctioned. If no sensor is required on Aux 1, select "None Connected" in the
program.
This message will display anytime the board is not receiving a signal from the Aux 2
when close button is pressed. Whether it is not connected, activated, or has
malfunctioned. If no sensor is required on Aux 2, select "None Connected" in the
program menu.
This message will display anytime the board is receiving a signal from the open limit
switch and the open button is pushed.
This message will display anytime the board is receiving a signal from the close limit
switch and the open button is pushed.
This message will display when the operator is powered up, and the auxiliary contacts
board is connected to the main board via wiring harness.
This message will display anytime the door is not on the fully open or close limit switch.