Raynor ControlHoist 2.0 STANDARD Installation Instructions And User Manual

Hide thumbs Also See for ControlHoist 2.0 STANDARD:

Advertisement

ControlHoist 2.0
STANDARD
INSTALLATION INSTRUCTIONS
-NOT FOR RESIDENTIAL USE-
-FOR INDOOR USE ONLY-
PLEASE READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION. IT IS
IMPORTANT THAT THIS OPERATOR BE INSTALLED CORRECTLY IN ORDER TO
ACHIEVE SAFE AND PROPER OPERATION.
THIS OPERATOR HAS BEEN SUPPLIED FROM THE FACTORY WITH CONSTANT
PRESSURE TO OPEN AND CLOSE. IF OTHER WIRING TYPES ARE REQUIRED,
A PHOTO ELECTRIC CONTROL MODEL OSE-S5000 BY VITECTOR FRABA, MODEL
HAE00056 BY LINEAR CORP, OR MILLER ELECTRIC REVERSING EDGE MODEL
ME WITH BLUE COLOR BAND IS REQUIRED.
SAVE THESE INSTRUCTIONS
INSTALLER: ATTACH THIS BOOKLET TO WALL
RAYNOR GARAGE DOORS DIXON , ILLINOIS 61021
AND
USER GUIDE
Model CST
Industrial Duty
BELT DRIVE
Trolley
IMPORTANT:
NEXT TO PUSH BUTTON.
Rev. 06/21
5973129-1

Advertisement

Table of Contents
loading

Summary of Contents for Raynor ControlHoist 2.0 STANDARD

  • Page 1 HAE00056 BY LINEAR CORP, OR MILLER ELECTRIC REVERSING EDGE MODEL ME WITH BLUE COLOR BAND IS REQUIRED. SAVE THESE INSTRUCTIONS INSTALLER: ATTACH THIS BOOKLET TO WALL NEXT TO PUSH BUTTON. Rev. 06/21 RAYNOR GARAGE DOORS DIXON , ILLINOIS 61021 5973129-1...
  • Page 2 Claims for defects in material and workmanship covered by this warranty shall be made in writing with proof of purchase to the dealer from whom the product was purchased or call Raynor at 1-800-4 -RAYNOR within the warranty period. Raynor may choose to have the product returned for inspection.
  • Page 3: Important Installation Instructions

    IMPORTANT INSTALLATION INSTRUCTIONS WARNING - Failure to follow these precautions may result in severe personal injury or death. 1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2. Door must be installed properly and balanced before installing the operator. An improperly balanced door can be hazardous and cause severe injury. Repairs to cables, spring assemblies and other hardware must be made by a qualified door installer.
  • Page 4: Preliminary Inspection

    PRELIMINARY INSPECTION Before proceeding with the installation of your Raynor Trolley Operator, it is advisable that you check the following items: PACKAGING Check the nameplate located on the powerhead to verify that the correct operator was shipped to you. Also check Check shipping container for damage.
  • Page 5: Installation Instructions

    2 inches above high rise point marked on header. Secure bracket to wall using either lag screws or self tapping screws furnished in hardware package. Caution: Raynor recommends an intermediate hanger on all installations over 10 feet high. Warning: With hangers in place, tighten all bracket bolts. Remove Be certain mounting bracket is level temporary hanger or ladder.
  • Page 6 Fig. 7 shows motion detectors, or photo eyes are required, you must use the type of bracing recommended by Raynor for the a wire type of CL2 or equivalent. Trolley Operator. Bracket should be located so holes on door bracket line up with top rollers on door.
  • Page 7 MINIMUM WIRE SIZE FOR SINGLE-PHASE MOTORS limit nuts in desired position, make certain that limit nut keeper is engaged in grooves on limit nuts. When making Volts 0-25 Ft. 50 Ft. 100 Ft. 150 Ft. 200 Ft. fine adjustments, turn nut no more than 1/4 turn at a time. 0.33 To stop door earlier, move limit nut closer to limit switch.
  • Page 8 LOGIC BOARD FUNCTIONS AND CONNECTIONS Program Button Limit Switch/Radio Control Terminal Block 1 Connection LED Display Chain Hoist Interlock SEN2 SEN2 SEN1 SEN1 STOP CLSE OPEN Chain Hoist Interlock Jumper LIMITS/RADIO 24VAC 24VAC AUX2 Terminal Block 2 AUX1 SINGL ILOCK External Interlock High Voltage Wire Harness Connection...
  • Page 9 LOGIC BOARD PROGRAMMING The logic board is programmed at the factory with constant pressure to open and close. Follow the instructions below to program the board for your application. Programming Notes: 1. Use the Open, Close and Stop buttons on the board when programming. 2.
  • Page 10 8. If " VENTILATION (N.O) " was selected, the distance the door is to open needs to be set. The display should read " OPEN VENT TIME " , the distance is determined by the number of seconds the door will open. This is done in 1 second intervals from 3 to 30 seconds.
  • Page 11 Only have a trained door systems technician make repairs to cables, springs and other hardware. 7. Only use Raynor approved reversing device as explained on front cover of this installation booklet. Failure to use a Raynor approved device may cause severe injury or death.
  • Page 12: Periodic Inspection And Maintenance

    PERIODIC INSPECTION AND MAINTENANCE Your Raynor electric door operator was designed to give dependable service with a minimum amount of maintenance. After proper installation and adjustment, by a qualified installer, little is required in the way of miantenance except for...
  • Page 13 ON BOARD STATUS LIGHTS On = Stop button connected and working. 1. Stop (D14) Off = Stop button pressed or NOT connected. On = Open button sending signal (pressed) 2. Open (D12) Off = Open button is not sending signal. On= Close button sending signal (pressed) 3.
  • Page 14: Lcd Display Messages

    LCD DISPLAY MESSAGES The LCD display will read "locked Out" when either the on board chain hoist interlock, or "Locked Out" the door interlock, on terminal block 2 is activated. These connections will have a jumper when not required. When in Timer to close mode (TCS), and door is in the open position, if the stop button "TCS Paused"...
  • Page 15 COMMERCIAL OPERATOR TROUBLESHOOTING LIST SYMPTOM PROBABLE CAUSE PROBABLE SOLUTION 1. Connect Operator to power source. 2. Check voltage at L1 & L2 for single phase and at L1, L2 & L3 1. No power to Operator. for three phase. 3. Check for blown fuse or tripped circuit breaker. 2.
  • Page 16 Common Mistakes that could damage or disrupt a ControlHoist 2.0 Logic Board High Voltage Wiring High voltage wires must never be ran in the same conduit as low voltage wiring (which includes push-button wiring, interlock devices, and any 24v accesory device). High voltage wires supplying power to the operator can create a magnetic field around themselves.
  • Page 17 Auxiliary Board (when supplied) 1. The contacts on the auxiliary board are rated for 3 amps. If the device you are activating draws more than the rated 3 amps, you will need to drive a relay that has the correct rating. Then use the dry contacts of that relay to activate the device.
  • Page 18 **Bottom Fixture Danger Label *Push Button Placard Locate Near Push Button **Door Safety Label **Bottom Fixture Danger Label * Label Supplied With Operator ** Label Supplied With Raynor Door NOTE: Placement of Labels may vary from what is shown. 5973129-18...

This manual is also suitable for:

Cst

Table of Contents