Available languages

Water connection

Connect the appliance to a drinking water line.
The water may be connected only by a
competent plumber according to the local
regulations of the appropriate water supply
company. A cold water connection is necessary
for operating the automatic ice maker.
The water supply pressure must be between 30 and
120 p.s.i. (2.06 and 8.27 bar). In case a reverse
osmosis system is used the pressure of the water
supply from this system going to thewater inlet
valve of the refrigerator needs to be between 30
and 120 p.s.i. (2.06 and 8.27 bar). The installation
must correspond to the local plumbing regulations.
A separate shut-off valve should be installed in the
cold-water inflow. The shut-off valve should not be
located behind the appliance. It is recommended
that you mount the shut-off valve directly next to
the appliance or at another place which is easily
accessible.
When installing the water connection, pay
attention to the permissible installation area for
the water mains. For connection to the drinking
water mains use only water pipes which are
suitable for drinking water.
Observe national regulations and the connection
conditions of the local water supply companies.