ECP Status Codes

When the 7720PLUS radio is set up in ECP mode, it sends to the control panel the status of its
battery, the incoming AC voltage, the tamper and any RF failures. The status is displayed on the
control panel's remote keypad in the form of a four-digit numeric usually preceded by the label "Long
Rnge Fail". These codes will not clear from the remote keypad until a code-off sequence is entered
and the fault condition has cleared. The status codes are broken out as follows:
Status CodeExplanation
0000
0400
3000
0880
0060
(The following codes will never be combined; each is mutually exclusive)
0001
0005
0006
0007
Codes 1& 6 require factory service.
Panel lost communication with the 7720PLUS radio
7720PLUS Power On/Reset
7720PLUS lost AC power input
7720PLUS tamper detected (cover removed from radio)
7720PLUS Battery is Low
7720PLUS has internal radio fault and cannot transmit*
7720PLUS Radio Fault (BadVSWR or low RF output.Check
antenna, connections and cable)
7720PLUS EEPROM and/or RAM is corrupt (internal CRC is bad)*
7720PLUS had not been programmed