Declares that the product: Control box for 1 motor, ideal for sliding doors: CP.BISON OTI conforms with the requirements of the following EU Directives: • DIRECTIVE 2004/108/CE OF THE EUROPEAN PARLIAMENT AND COUNCIL, 15 December 2004, in relation to the...
INPUT/OUTPUT FUNCTIONS CAUTION!: The CP.BISON OTI control unit is equipped with an embedded anti-crash device (amperometric sensor). Given the overall dimensions of the door leaves for which the device is intended, the latter cannot be considered a safety device. It is therefore STRICTRLY mANDATORY to install activated protection sen- sitive edges according to regulations in force.
Page 7
* Bison 25: <+> INVERTER The CP.BISON OTI control unit is provided with serial connections for the control of a pre-installed inverter on the gear motors of the BISON series. The inverter allows to enhance the functional performance of the motor as regards control of the torque, speed and safety.
Page 8
PARAmETERS, LOGIC AND SPECIAL FUNCTIONS The tables below describe the individual functions available in the control unit. PARAmETERS (PAR) mENU FUNCTION mEmO mIN-mAX-(Default) Automatic closure time. It is activated only with “TCA” logics:ON 1-240-(40s) At the end of the preset time, the control unit starts a new closing operation. The passage left open by the door/gate leaf during the partial opening controlled Tped by the pedestrian inoput, is adjusted.
Page 9
LOGIC (LOG) mENU FUNCTION mEmO ON-OFF-(Default) Enables or disables automatic closing On: automatic closing enabled (OFF) Off: automatic closing disabled Enables or disables multi-flat function. On: multi-flat function enabled. The step-by-step and perdestrian commands have (OFF) no effect during the opening phase. Off: multi-flat function disabled.
Page 10
The code programmable transmitters is enabled or disabled. On: Radio receiver enabled only for rolling-code transmitters. CVAR (OFF) Off: Receiver enabled for rolling-code and programmable code transmitters (self- learning and Dip Switch). The remote storage of the radio transmitter codes is enabled or disabled (see par. REMOTE LEARNING).
Page 11
PASSWORD (CODE) It allows to type in an access protection code to the programming of the control unit. A four-character alphanumeric code can be typed in by using the numbers from 0 to 9 and the letters A-B-C-D-E-F. The default value is 0000 (four zeros) and shows the absence of a protection code. While typing in the code, this operation can be cancelled at any moment by pressing keys + and –...
Page 12
The TDEC time is theoretical by reason of the fact that as soon as the speed reaches the value preset by SLDS, braking at constant speed starts until reaching the SWC (SWO) limit switch. Once the limit switch is reached, the gate/door continues its movement for a period of time adjusted by BLC parameter, until entire stop.
LCD DISPLAY The LCD display can be turned by 180°. - Cut off mains power supply - Press OK - While keeping OK pressed, reset the mains power supply - Keep OK pressed (around 5 sec) until the software version appears, turned by 180°. Normally proceed with programming.