OUTDOOR UNIT:
COOLING
performance at
Rating conditions
Running Amps.
Power input
Full load conditions
Running Amps.
Power input
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
NOTE: Data referred to indoor unit
For other indoor unit models could be the same difference.
All manuals and user guides at all-guides.com
AER522SC
Indoor Unit
Fan Motor
A
0,39
Kw
0,075
A
0,39
Kw
0,075
AWR522CL
23
Outdoor unit
Fan Motor
Compressor
230V 1-Phase 50 Hz
0,55
12,1
0,124
2,551
0,55
14,1
0,124
3,101
model.
Complete Unit
13,0
2,750
15,0
3,300