  • Page 1 C L I N I C D ES I G N INSTRUCTION MANUAL HOSPITAL BED IMPULSE KL...
  • Page 3 Dear Customers, By purchasing a hospital bed from Malsch care & clinic design ® you have obtained a long-lasting medical device with functions that meet all the requirements of everyday hospital care while maintaining the highest standards of safety. Thank you very much for the trust you have placed in us.
  • Page 4: Table Of Contents

    Contents Product range Function illustration Specific function IMPULSE KL hospital bed with undercarriage Editions 300 / 400 / XL Environmental sustainability IMPULSE KL hospital bed with Notes to the instruction manual undercarriage Edition 200 Pictograms / symbols Description of function...
  • Page 5 Removable head / foot boards Warranty and service Potential equalisation Customer service Function illustration Declaration of conformity IMPULSE KL hospital bed with undercarriage Editions 300-P / 400-P Certificates Additional safety instructions or beds used in psychiatric wards DS-P side rail adjustment...
  • Page 6: Product Range

    PRO D U C T R A N G E IMPULSE KL hospital bed IMPULSE KL hospital bed with undercarriage Edition 200 with undercarriage Edition XL IMPULSE KL hospital bed IMPULSE KL hospital bed with undercarriage Edition 300 / 400...
  • Page 7: Specific Function

    EN V I RO N M EN TA L S U S TA I N A B I L IT Y The hospital beds made by Betten Malsch GmbH are used in the Betten Malsch GmbH hospital beds are manufactured in line with care of patients with physical limitations.
  • Page 8: Notes To The Instruction Manual

    The instruction manual must be used current subject! for this training. This instruction manual has been written for the IMPULSE KL hospital bed. The images, graphics and texts it contains may differ from the equipment supplied. The manufacturer offers technician training for maintenance and servicing work on their hospital beds.
  • Page 9: Safety Instructions

     p. 16 of this instruction manual. The IMPULSE KL hospital bed features a battery-operat- ed emergency mode. This allows the one-off lowering of In the event of any faults or defects that could endanger the sleeping surface in the event of a power cut.
  • Page 10 The hand controller can be placed flexibly. When placing In line with the standard DIN EN 60601-2-52:2016, when the hand controller, take care to ensure that it cannot be choosing a mattress, it is important that there is a minimum triggered accidentally (e.
  • Page 11 Electrically operated hospital beds are active medical prod- next inspection. The required protocols concerning checks ucts and must be maintained according to Article 7 of the already performed must be appended to the inventory. Medical Devices Operator Ordinance (MedProd-BetrV.) These maintenance measures must be carried out regularly Proper execution and traceable documentation of the (at least once per year).
  • Page 12 The use of accessories, transducers and cables other than those specified or provided by Betten Malsch GmbH can cause increased emissions of electromagnetic interference or reduce the electromagnetic interference resistance of the device and thus lead to faulty operation.
  • Page 14: Technical Data

    Load capacity (Anti-) Upper leg Back rest [cm] [cm] ment [cm] max. Trendelenburg adjustment adjustment IMPULSE KL Total 200 kg hospital bed with 135 kg patient – 43° 71° undercarriage 211 x 104 200 x 90 43 to 83 approx. 100 kg...
  • Page 15: Electric Drives

    EL EC T R I C D R I V E S Model Edition 200 Edition 300 Edition 400 Edition XL Edition 300 Edition 400 Drive set Dual drive Standard Standard Standard Basic Basic Electrical connection 100 - 240 V AC 50 / 60 Hz Output voltage 35 V DC 2 A 35 V DC 2,5 A...
  • Page 16: Rating Plate

    T_o : 18 min. Protection class: IPX4 Example of a rating plate without UDI of the IMPULSE KL hospital bed R ATI N G PL AT E W IT H U D I Malsch Betten Malsch GmbH | Rohbergstraße 9 | D-36208 Wildeck-Obersuhl Tel.: +49 (0) 6626 915-100 | info@bettenmalsch.de | bettenmalsch.com...
  • Page 17 The rating plate is located on the underside of the sleeping sur- Directive 2002 / 96 / EC relating to old electrical and face, at the head of the bed on the right. To inspect the rating electronic equipment plate, raise the head section to the upper position. Conformity marking in line with the Notes: Medical Device Directive...
  • Page 18 Labels A separate sticker to the right of the rating plate refers to the labels described below: Symbol: Label indicating beds for adults used for medical pur- poses in line with IEC 60601-2-52:2009 / AMD:2015 The following table contains information concerning mattress siz- es depending on the sleeping surface dimensions: Mattress size [cm] Sleeping surface...
  • Page 19: Symbols Of Staff Controller

    S Y M B O L S O F S TA FF CO N T RO L L ER ADJUSTMENTS LOCKING OF FUNCTIONS CPR (electric) Lock back rest adjustment Shock position Lock upper leg support LED red = Back rest up Lock auto contour locked Upper leg support up...
  • Page 20: Hand Controller Symbols

    H C -14 6 H A N D CO N T RO L L ER S Y M B O L S IMPULSE KL hospital bed with undercarriage Editions 300(-P) / 400(-P) / XL Drive type “Standard” with staff controller...
  • Page 21: Hand Controller Symbols

    H C -147 H A N D CO N T RO L L ER S Y M B O L S IMPULSE KL hospital bed with undercarriage Edition 200 Locking function Drive set without staff controller positioned on the back of the hand controller for restricting operation by resident.
  • Page 22: Function Illustration

    FU N C TI O N I L LU S T R AT I O N IMPULSE KL hospital bed with undercarriage Editions 300 / 400 / XL The IMPULSE KL hospital bed with undercarriage Edition XL is only available with reinforced metal mesh sleeping surface (Fig. p. 23).
  • Page 23 Wall bumper (4x surrounding the bed) Vertical side rail with one-handed operation (EVGS) (1)(2)* Reinforced metal mesh sleeping surface in IMPULSE KL ISO standard rail on bed frame hospital bed with undercarriage Edition XL ISO standard rail integrated into the side rail for (E)VGS...
  • Page 24: Impulse Kl Hospital Bed With Undercarriage Edition

    FU N C TI O N I L LU S T R AT I O N IMPULSE KL hospital bed with undercarriage Edition 200...
  • Page 25 S TA N DA R D D E S I G N IMPULSE KL hospital bed with undercarriage Edition 200 Adjustable lower leg support (notched bracket) Adjustable upper leg support Static seat panel Adjustable back rest Mattress holder Potential equalisation (external)
  • Page 26: Description Of Function

    D E SC R I P T I O N O F F U N C T I O N Mechanical back rest release / CPR Depending on the design and type of hospital bed, it can be put into the following positions by adjusting the back rest, the upper leg and the lower leg supports as well as the height of the bed: Design with VGS Handle at the head end near the outer side rail guide...
  • Page 27: Adjustable Upper / Lower Leg Support

    (Auto contour operating buttons) Caution! Before pressing the lever, ensure that there are no objects or parts of the body below the back rest. Manually relieve the weight on the back Using the button function adjusts the back rest and upper leg rest during adjustment to prevent it dropping in an support equally.
  • Page 28: Low Position / Fall Prevention

    In- The low bed IMPULSE KL with undercarriage Edition 400 can be correct settings may result in permanent injury to moved to the low position in one continuous movement using the patient.
  • Page 29: Hand Controller Locking Function

    The electrical unit combines state-of-the-art technology and single- fault safety. The IMPULSE KL hospital bed with undercarriage Editions 300 / 400 / XL offers three different adjustment options: The locking function is a further safety precaution. The locking function is located on the back of the hand controller...
  • Page 30: 5Th Castor (Optional)

    5th castor (optional) The 5th castor installed in the middle of the bed allows for easy rotation of the bed when transporting patients. It is locked by means of a foot pedal and allows the bed to be easily rotated on its own axis, making it simpler to manoeuvre.
  • Page 32: Gs Side Rail Adjustment

    GS side rail adjustment Split side rails In standby position, the side rails are located next to the sleeping Fig. 1 surface and thus prevent the mattress from slipping. (Fig. 1) The side rails are raised by tilting them upwards. In this middle position, they prevent the patient falling out of bed.
  • Page 33 GS side rail dimensions When using the ABS / metal lattice sleeping surface...
  • Page 34: Vgs Side Rails Adjustment

    VGS side rails adjustment Vertically retractable split side rails Pos. 2 In standby position, the side rails are located next to the sleeping Pos. 1 surface. In this position, they prevent the mattress from slipping. To raise the side rails, pull them upwards with both hands until they engage with an audible click.
  • Page 35: Evgs Side Rails Adjustment

    Seitengitterverstellung VGS EVGS side rails adjustment geteilte Seitensicherung mit Einhand-Bedienung Vertically retractable split side rails with one-handed operation Die Seitengitter befinden sich in Ruheposition seitlich an der Halt Liegefläche und geben dieser Lage der Matratze gegen Verschieben. In standby position, the side rails are located next to the sleeping surface.
  • Page 36 VGS side rail dimensions When using the ABS / metal lattice sleeping surface...
  • Page 37: Esg Side Rail Adjustment

    ESG side rail adjustment Fig. 1 One-part side rail (IMPULSE KL hospital bed with undercarriage Edition 200) The side rails are in the standby position (Fig. 1) and allow the patient to get into and out of bed easily. In order to raise the side rail, grab it by the upper bar and Fig.
  • Page 38: Integrated Sleeping Surface Extension With Quick Release

    (IMPULSE KL hospital bed with undercarriage Edition 300) The IMPULSE KL hospital bed with undercarriage Edition 300 is equipped at the factory with an integrated sleeping surface exten- sion. The sleeping surface can thus be extended by 10 or 20 cm by means of a quick release mechanism.
  • Page 39: Integrated Sleeping Surface Extension

    IMPULSE KL hospital bed with undercarriage Edition 400 (IMPULSE KL hospital bed with undercarriage Edition 400) The IMPULSE KL hospital bed with undercarriage Edition 400 is equipped at the factory with an integrated sleeping surface extension. The sleeping surface can be extended by 10 or 20 cm using two locking bolts at the lower foot end.
  • Page 40: Removable Head / Foot Boards

    Removable head / foot boards Potential equalisation The standard IMPULSE KL hospital bed has head / foot boards The IMPULSE KL hospital bed with undercarriage Editions that can be removed without the use of tools. These boards can 300 / 400 / XL is equipped with a standard protective conductor.
  • Page 42: Function Illustration

    FU N C TI O N I L LU S T R AT I O N IMPULSE KL hospital bed with undercarriage Editions 300-P / 400-P...
  • Page 43 D E S I G N F O R P S YC H I AT R I C WA R DS IMPULSE KL hospital bed The following differences from the standard equipment are a re- with undercarriage Editions 300-P / 400-P...
  • Page 44: Additional Safety Instructions

    A D D IT I O N A L S A FE T Y I N S T RU C T I O N S F O R B EDS U S ED I N P S YC H I ATR I C WA R DS Removable accessories such as trapeze bars, IV drip stands and accessories of the DIN standard rail etc.
  • Page 45: Ds-P Side Rail Adjustment

    DS-P side rail adjustment Full-length, removable side rail Fig. 1 Fig. 2 The full-length, removable side rail is mounted at the sides into the recesses of the head / foot boards and fixed to the frame of the head / foot board with cam levers (Fig. 2). Raising function: Pull up the upper side rail bar (Fig.
  • Page 46: Iso Standard Rail With Restraint Grid

    ISO standard rail with restraint grid Caution! Always heed the restraint regulations of The IMPULSE KL hospital bed with undercarriage for psychiatric your workplace, your facilityʼs internal restraint wards Editions 300-P / 400-P comes with full length ISO standard protocol and the current legal regulations of your rails with restraint grids on both sides of the bed.
  • Page 47: Maintenance

    Only original replacement parts from Betten Malsch GmbH are permitted to be used. The spacing requirements stated in BS EN 60601-2-52 are to be used to check the level of protection.
  • Page 48 The largest dimension in at least one direc- If D ≥ 250, tion of every opening below the side rail. F ≤ 60 If D ≤ 60, F ≤ 120 Length of the side rail(s) G ≥ 2 / 3 H Inner distance between head and foot Fig.
  • Page 49: Battery Replacement

    5. Visual inspection of mains connection cable 9. Measurements in line with BS EN 62353 Observe the following points with regard to the mains connec- Check the electrical components of the hospital bed as specified tion cable: in BS EN 62353. Measure the leakage current with the help of the equivalent leakage current test.
  • Page 50: Maintenance Intervals

    M A I N T EN A N C E I N T ERVA L S Every two years and after every emergency lowering § Replacement of the two 9 V block batteries § If the 9 V block batteries are not replaced during the maintenance interval or after use, the electric emergen- cy lowering function will cease to work.
  • Page 51: Delivery And Assembly

    D EL I V ERY A N D A S S EM B LY Assembly of head / foot board / sleeping surface Betten Malsch GmbH hospital beds are generally delivered fully assembled, or are assembled on site by company technicians or authorised staff.
  • Page 52: Disposal Instructions

    D I S P OS A L I N S T RU C T I O N S The service life of the hospital bed is specified as ten years if used Battery disposal appropriately. § Any individual removed batteries that can no longer be Disposal instructions used must be disposed of properly as defined by Di- rective 2006 / 66 / EC (implemented in Germany in the...
  • Page 53: Troubleshooting

    T RO U B L ES H OOT I N G The adjustment Malfunction Possible cause Possible solution time or safe Drives cut out working load has Allow the drive Mains cable not Plug in the after a long period been exceeded system to cool plugged in...
  • Page 54: Product Safety

    PRO D U C T S A FE T Y This product bears the CE seal and therefore meets the requirements of the applicable German and European safety standards. Standard Comment MPDG Medical devices implementation act Regulation (EU) 2017 / 745 Medical Device Regulation (MDR) BS EN ISO 13485 Medical devices.
  • Page 55: Cleaning And Disinfection

    The hospital bed may not be disinfected in an automated wash station. Betten Malsch GmbH recommends the products listed by the RKI for disinfection. The detergents used for disinfection must only be used in line with the manufacturerʼs instructions.
  • Page 56 Safe decommissioning / storage Proceed as follows to safely decommission the bed or prepare the bed for storage: § Disconnect the bed from the power by pulling out the mains plug. § Activate the brake system. Storage § Charge the (optional) battery regularly to prevent deep discharge.
  • Page 57: Electromagnetic Compatibility (Emc)

    EL EC T RO M AG N E T I C CO M PAT I B I L IT Y (EM C ) The bed is intended for operation in the electromagnetic environments listed below. The customer or user of the bed must ensure that it is used in a suitable environment.
  • Page 58 Magnetic IEC 61000-4-8 30 A / m 30 A / m Power-frequency magnetic fields must fields with correspond to the typical value found in the 50 / 60 Hz 50 / 60 Hz energetic rated business and hospital environments. frequencies Electrical IEC 61000-4-4 ±...
  • Page 59 Interference resistance of enclosure ports to high-frequency wireless communication equipment Test frequency Band [MHz] Service Modulation Maximum Distance [m] Immunity test [MHz] power [W] level [V/m] 380 to 390 TETRA 400 Pulse modulation 16 HZ 430 to 470 GMRS 460, Frequency FRS 460 modulation...
  • Page 60: Warranty And Service

    WA R R A N T Y A N D S ERV I C E D EC L A R AT I O N O F CO N F O R M IT Y By purchasing a hospital bed from Betten Malsch GmbH, you have chosen a premium, high-quality product.
  • Page 61: Certificates

    Der Nachweis der regelkonformen Anwendung wurde erbracht und wird gemäß TÜV PROFiCERT-Verfahren bescheinigt für und wird gemäß TÜV PROFiCERT-Verfahren bescheinigt für und wird gemäß TÜV PROFiCERT-Verfahren bescheinigt für Betten Malsch GmbH Betten Malsch GmbH Betten Malsch GmbH Rohbergstraße 9 Rohbergstraße 9 Rohbergstraße 9...
  • Page 62 Notes...
  • Page 63 Notes...
  • Page 64 Item no. 91300 102102.0 DE, Edition 08 / 2021, Rev. 2.0 Colours may vary Subject to technical changes Betten Malsch GmbH | Rohbergstraße 9 | 36208 Wildeck-Obersuhl | Germany Tel.: +49 (0) 6626 915-100 | Fax: +49 (0) 6626 915-116 bettenmalsch.com | info@bettenmalsch.de...