7
|

Maintenance and service

7 Maintenance and service

7.1 Overview: Maintenance and service

User reference guide
54
The installer has to perform a yearly maintenance. You can find the contact/
helpdesk number via the user interface.
1 Go to [8.3]: Information > Dealer information.
As end user, you have to:
Keep the area around the unit clean.
Keep the user interface clean with a soft damp cloth. Do NOT use any detergents.
Regularly check if the water pressure is above 1 bar.
Carry out a visual check of the water level inside the storage tank: Check if the
red level indicator is visible. If NOT, add water to the storage tank (for details see
Installer reference guide).
Refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent gases into the
atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
NOTICE
Applicable legislation on fluorinated greenhouse gases requires that the refrigerant
charge of the unit is indicated both in weight and CO
Formula to calculate the quantity in CO
refrigerant × total refrigerant charge [in kg] / 1000
Please contact your installer for more information.
WARNING: FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
WARNING
Do NOT pierce or burn refrigerant cycle parts.
Do NOT use cleaning materials or means to accelerate the defrosting process
other than those recommended by the manufacturer.
Be aware that the refrigerant inside the system is odourless.
equivalent.
2
equivalent tonnes: GWP value of the
2
EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678719-1 – 2021.11