Advertisement

Quick Links

Installation and Operational Instructions for
®
ROBA-stop
-S brake Type 856. _ _ _ . _
Size 11
Please read these Operational Instructions carefully and follow them accordingly!
Ignoring these Instructions may lead to malfunctions or to brake failure, resulting in damage to other parts.
These Installation and Operational Instructions (I + O) are part of the brake delivery.
Contents:
Page 1: - Contents
- Safety and Guideline Signs
- Guidelines on EU Directives
Page 2: - Safety Regulations
Page 3: - Safety Regulations
Page 4: - Safety Regulations
Page 5: - Brake Illustrations
- Parts List
Page 6: - Technical Data
- Design
- Function
- State of Delivery
- Installation Conditions
Page 7: - Brake Attachment
- Tacho Attachment (Option)
- Air Gap Inspection
Page 8: - Air Gap Re-adjustment
- Replacing the Rotor
- Electrical Connection and Wiring
Page 9: - Electrical Connection and Wiring
Page 10: - Electrical Connection and Wiring
Page 11: - Release Monitoring
Page 12: - Braking Torque Adjustment
- Emergency Release
Page 13: - Anti-condensation Heating (Option)
- Condensation
- Disposal
- Malfunctions / Breakdowns
Guidelines on the Declaration of Conformity
A conformity evaluation has been carried out for the product (electromagnetic safety brake) in terms of the EC Low
Voltage Directive 2006/95/EC. The declaration of conformity is set out in writing in a separate document and can be
requested if required.
Guidelines on the EMC Directive (2004/108/EC)
The product cannot be operated independently in terms of the EMC directive.
Due to their passive quality, brakes are also non-critical equipment according to the EMC.
Only after integration of the product into an overall system can it be evaluated in terms of the EMC.
For electronic equipment, the evaluation has been verified for the individual product in laboratory conditions, but not in the
overall system.
Guidelines on the Machinery Directive (2006/42/EC)
The product is a component for installation into machines according to the Machinery Directive 2006/42/EC.
The brakes can fulfil the specifications for safety-related applications in connection with other elements.
The type and scope of the required measures result from the machine risk analysis. The brake then becomes a machine
component and the machine manufacturer assesses the conformity of the safety device to the directive.
It is forbidden to start use of the product until you have ensured that the machine accords with the regulations stated in the
directive.
Guidelines on the ATEX Directive
Without a conformity evaluation, this product is not suitable for use in areas where there is a high danger of explosion.
For application of this product in areas where there is a high danger of explosion, it must be classified and marked
according to directive 94/9/EC.
19/11/2010 TK/KE/GC/SU
Page 1 of 13
Please keep them handy and near to the brake at all times.
Chr. Mayr GmbH + Co. KG
Eichenstraße 1
D-87665 Mauerstetten
Germany
Safety and Guideline Signs
DANGER
Immediate and impending danger which can
lead to severe physical injuries or to death.
CAUTION
Danger of injury to personnel and
damage to machines.
Please Observe!
Guidelines on important points.
Please Observe!
According to German notation, decimal points
in this document are represented with a comma
(e.g. 0,5 instead of 0.5).
Tel.: 08341 / 804-0
Fax: 08341 / 804-421
http://www.mayr.de
E-Mail:
info@mayr.de
(B.8.3.1.GB)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ROBA-stop-S 856 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mayr ROBA-stop-S 856

  • Page 1 For application of this product in areas where there is a high danger of explosion, it must be classified and marked according to directive 94/9/EC. 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de...
  • Page 2: Safety Regulations

    Only carry out installation, maintenance and repairs in a de-energised, released state and secure the system against inadvertent switch-on. 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de...
  • Page 3 Protective circuit: When using DC-side switching, the coil must be protected by a suitable protective circuit according ® to VDE 0580, which is integrated in mayr -rectifiers. To Appointed Use protect the switching contact from consumption when using ®...
  • Page 4 - the brakes are worked on unprofessionally. - the brakes are handled or operated incorrectly. Guarantee The guarantee conditions correspond with the Chr. Mayr GmbH + Co. KG sales and delivery conditions. ® Mistakes or deficiencies are to be reported to mayr once!
  • Page 5 M16 x 25 Microswitch Type tag * The number of thrust springs depends on the braking torque, see page 12 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de...
  • Page 6: Technical Data

    The ROBA-stop -S brakes reliably and safely in the event of a power switch-off, a power failure or an EMERGENCY STOP. 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de...
  • Page 7: Feeler Gauge

    Fig. 8 8. Check the air gap acc. section "Air Gap Inspection". Emergency release Fig. 6 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de Page 7 of 13...
  • Page 8 For brake release at max. air gap and with a braking torque adjustment > 100 % of the nominal value stated in the catalogue, overexcitation is mandatory. 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de...
  • Page 9 The spring forces also influence the brake separation times t Higher spring forces increase the separation times t and lower spring forces reduce the separation times t 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de...
  • Page 10: Connection Examples

    7/8: AC voltage supply (AC voltage) Depending on the application, the switching contact can also be for anti-condensation heating ® protected by other protective circuits (e.g. mayr -spark quenching unit, half-wave and bridge rectifiers), although this 9/10: Release monitoring may of course then alter the switching times.
  • Page 11 +0,35 0,45 Nominal air gap Fig. 12 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de Page 11 of 13 Germany E-Mail: info@mayr.de...
  • Page 12 (see Fig. 2). Do not damage the O-rings (18 and 19)! Observe the tightening torque of 46 Nm! Fig. 13 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de...
  • Page 13 Adjust the switch again does not emit a signal Switching position misaligned Replace the switch Defective microswitch 19/11/2010 TK/KE/GC/SU Chr. Mayr GmbH + Co. KG Tel.: 08341 / 804-0 Eichenstraße 1 Fax: 08341 / 804-421 D-87665 Mauerstetten http://www.mayr.de Page 13 of 13...