INSTRUCTION MANUAL
T30
1MN0107 REV.2
operates with ISO9001 certified quality system
TECSYSTEM S.r.l.
20094 Corsico (MI)
Tel.: +39-024581861
Fax: +39-0248600783
http://www.tecsystem.it
R. 1.5 26/11/20
ENGLISH
"Translations of the original instructions"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T30 and is the answer not in the manual?

Questions and answers

Summary of Contents for TECSYSTEM T30

  • Page 1 INSTRUCTION MANUAL 1MN0107 REV.2 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.5 26/11/20 ENGLISH “Translations of the original instructions”...
  • Page 2: Table Of Contents

    INTRODUCTION First of all we wish to thank you for choosing to use a TECSYSTEM product and recommend you read this instruction manual carefully: You will understand the use of the equipment and therefore be able to take advantage of all its functions.
  • Page 3: Safety Requirements

    POWER SUPPLY The T30 control unit can be supplied by 230Vac or 120Vac 50/60HZ, according to the model purchased. Before using it, make sure the power cable is not damaged, knotted or pinched. Do not tamper with the power cable.
  • Page 4: Accessories

    ACCESSORIES The following objects are present inside the box: Control unit Start guide and QR code TECHNICAL SPECIFICATIONS 230 Vac 120 Vac POWER SUPPLY 240Vac 120Vac Supply rated values 50/60HZ 50/60HZ INPUTS ● ● 2 series of PTC inputs 1 series for L1 (ALL1) ●...
  • Page 5: Front

    TECHNICAL SPECIFICATIONS 230 Vac 120 Vac Ambient operating temperature from -20°C to + 60°C ● ● Humidity 90% non-condensing ● ● BLEND PC/ABS housing UL 94V0 self-extinguishing ● ● Absorption 3VA ● ● Self-diagnostic circuit ● ● Protection treatment of the electronic part Option Option DISPLAY AND DATA MANAGEMENT...
  • Page 6: Power Supply

    POWER SUPPLY The T30 control unit can be supplied by 230 Vac or 120 Vac terminals L-N, according to the model purchased 50/60Hz ±10%. Before powering the device, always check the supply parameters printed on the label. When the unit is supplied directly by the secondary of the transformer to protect, it can be burnt out by strong overvoltages.This happens if the main switch is closed and the transformer has no load (blank test).
  • Page 7: Ptc" Type Temperature Sensors

    IMPORTANT NOTICE Before carrying out the isolation test of the electrical panel the control unit is installed on, disconnect it and the sensors from the power supply to prevent it from being seriously damaged. "PTC" TYPE TEMPERATURE SENSORS The PTCs can be compared to bimetallic thermostats where the contact opens and closes at the approximate temperature, defined as their operating characteristic (NAT=operating temperature).
  • Page 8: Warranty Conditions

    Returning used electrical devices: contact TECSYSTEM or your TECSYSTEM agent for information on the correct disposal of the devices. TECSYSTEM is aware of the impact its products have on the environment and asks its customers active support in the correct and environmentally-friendly disposal of its devices.