10 - OPTIONS AND ACCESSORIES

Options
No. Description
Star / delta start
25A Star / Delta start on each compressor
Unit equipped with supplementary water outlet
temperature sensor kit to be field-installed allowing 
Master/slave operation
58
master/slave operation of two units connected in
parallel
Single power
81
Unit power connection via one main supply connection Quick and easy installation
connection point
Unit without disconnect switch, but with short-circuit
No disconnect switch
82A
protection device
Evap. single pump
Unit equipped with an electrical power and control
84
power/control circuit
circuit for one pump evaporator side
E v a p . d u a l p u m p s
Unit equipped with an electrical power and control
84D
power/control circuit
circuit for two pumps evaporator side
Cond. single pump
Unit equipped with an electrical power and control
84R
power/control circuit
circuit for one pump condenser side
Evaporator with one
100A Evaporator with one pass more on the water side
pass more
Evaporator with one
Evaporator with one pass on the water side.
100C
pass less
Evaporator inlet and outlet on opposite sides.
Condenser with one
Condenser with three passes on the water side.
102A
pass more
Condenser inlet and outlet on opposite sides.
Condenser with one
Condenser with one pass on the water side.
102C
pass less
Condenser inlet and outlet on opposite sides.
Reinforced evaporator for extension of the maximum
21 bar evaporator
104
water-side service pressure to 21 bar (standard 10
bar)
Reinforced condenser for extension of the maximum
21 bar condenser
104A
water-side service pressure to 21 bar (standard 10
bar)
Reversed evaporator
107 Evaporator with reversed water inlet/outlet
water connections
Reversed condenser
107A Condenser with reversed water inlet/outlet
water connections
Two-directional communication board complying with
J-Bus gateway
148B
JBus protocol
Two-directional communication board complying with
Lon gateway
148D
Lon Talk protocol
Two-directional high-speed communication using
Bacnet over IP
149
BACnet protocol over Ethernet network (IP)
Output signal (0-10 V) to control the condenser water
Control for low cond.
152
temperature
inlet valve
Energy Management
EMM Control board with additional inputs/outputs.
156
Module
See Energy Management Module option chapter
Additional tests on the water heat exchangers: supply
Compliance with Swiss
197
(additional of PED documents) supplementary
regulations
certificates and test certifications
Low noise level
257 Evaporator sound insulation
Welded evaporator
266 Victaulic piping connections with welded joints
connection kit
We l d e d c o n d e n s e r
267 Victaulic piping connections with welded joints
water connection kit
Flanged evaporator
268 Victaulic piping connections with flanged joints
water connection kit
Flanged condenser
269 Victaulic piping connections with flanged joints
water connection kit
Conformance with
327 Specific regulatory documentation
Moroccan regulations
26
Advantages
Reduced start-up current
Optimised operation of two units connected in
parrallele operation with operating time equalisation
Permits an external electrical disconnect system
for  the  unit  (field-supplied),  while  ensuring  unit 
short circuit protection
Quick  and  easy  installation:  the  control  of  fixed 
speed pumps is embedded in the unit control
Quick  and  easy  installation:  the  control  of  fixed 
speed pumps is embedded in the unit control
Quick  and  easy  installation:  the  control  of  fixed 
speed pumps is embedded in the unit control
Optimise chiller operation when the chilled water
circuit is designed with low waterflows (high delta 
T evaporator inlet/oulet)
Easy to install, depending on site. Reduced
pressure drops
Adapted to sites where larger temperature
differences and smaller water flow rates are
required
Easy to install, depending on site. Reduced
pressure drops
Covers applications with a high water column
evaporator side (typically high buildings)
Covers applications with a high water column
condenser side (typically high buildings)
Easy installation on sites with specific requirements
Easy installation on sites with specific requirements
Connects the unit by communication bus to a
building management system
Connects the unit by communication bus to a
building management system
Easy and high-speed connection by ethernet line
to a building management system. Allows access
to multiple unit parameters
Simple installation: for applications with cold water
at condenser inlet (ex. ground-source, groundwater-
source, superficial water-source applications) the 
signal permits to control a 2 or 3-way valve to
maintain condenser water temperature (and so
condensing pressure) at acceptable values
Extended remote control capabilities (Set-point
reset, ice storage end, demand limits, boiler on/off
command...)
Conformance with Swiss regulations
3 dB(A) quiter than standard unit
Easy installation
Easy installation
Easy installation
Easy installation
Conformance with Moroccan regulations
Use for
61XWH range
3-5, 10
3-17
61XWHLZE /
61XWH-ZE
10-17,
61XWHHZE 10
3-17
3-10 Not
available for
61XWHHZE
3-10 Not
available for
61XWHHZE
3-10 Not
available for
61XWHHZE
3-17
3-17
3-17
3-17
3-17
3-17
3-17
3-17
3-17
3-17
3-17
3-17
3-17
3-17
5-17
3-17
3-17
3-17
3-17
3-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents