Viessmann VITOLADENS 300-C Service Instructions Manual page 46

Hide thumbs Also See for VITOLADENS 300-C:
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in the delivered condition
60:20
During DHW heating,
the boiler water tem-
perature is up to 20 K
higher than the set
DHW temperature
62:2
Cylinder primary pump
with 2 min run-on
65:0
Never adjust
67:40
In conjunction with the
Vitosolic solar control
unit: Third set DHW
value
6F:100
Maximum output for
DHW heating 100 %,
defaulted by the boiler
coding card
71:0
DHW circulation pump
"ON" according to time
program
72:0
DHW circulation pump
"ON" according to time
program
73:0
DHW circulation pump
"ON" according to time
program
General
76:0
Without LON communi-
cation module
46
Possible change
60:5
The difference between
to
the boiler water tempera-
60:25
ture and the set DHW
temperature is adjustable
from 5 to 25 K
62:0
Circulation pump without
run-on
62:1
Run-on time adjustable
to
from 1 to 15 min
62:15
67:0
Set DHW value adjusta-
to
ble from 0 to 60 °C
67:60
6F:0
Max. output during DHW
to
heating adjustable from 0
6F:100
to 100 %
71:1
OFF during DHW heating
to set value 1
71:2
ON during DHW heating
to set value 1
72:1
"OFF" during DHW heat-
ing to the second set
value
72:2
"ON" during DHW heat-
ing to the second set
value
73:1
During the time program
to
1x/h "ON" for 5 min
73:6
up to 6x/h "ON" for 5 min
73:7
permanently "ON"
76:1
With LON communication
module (automatic recog-
nition)