CAUTION STATEMENTS
Section 1
710-03261-00A
http://www.kontrolkalemi.com/forum/
Caution Statements
This symbol is used throughout this manual to draw attention to topics
of special importance to the installation and operation of the MVS soft
starter.
Caution Statements cannot cover every potential cause of equipment damage but
can highlight common causes of damage. It is therefore the installer's
responsibility to adhere to all instructions in this manual, to follow good electrical
practice and to seek advice before operating this equipment in a manner other than
as detailed in this manual.
•
Ensure that the MVS is completely isolated from the power supply before
attempting any work on the unit.
•
Entry of metal swarf into the cabinet can cause equipment failure.
•
Do not apply voltage to the control input terminals. These are active
24 VDC inputs and must be controlled with potential free circuits.
•
Ensure contacts/switches operating the control inputs are suitable for low
voltage, low current switching (ie gold flash or similar).
•
Ensure cables to the control inputs are segregated from AC power and
control wiring.
•
Some electronic contactor coils are not suitable for direct switching with
PCB mount relays. Consult the contactor manufacturer/supplier to see if
this is advisable.
•
Do not connect power factor correction capacitors to the output of the
MVS. If static power factor correction is employed, it must be connected to
the supply side of the MVS.
The examples and diagrams in this manual are included solely for illustrative
purposes. Users are cautioned that the information contained in this manual is
subject to change at any time and without prior notice. In no event will
responsibility or liability be accepted for direct or indirect or consequential damages
resulting from the use or application of this equipment.
WARNING – ELECTRICAL SHOCK HAZARD
The MVS contains dangerous voltages when connected to line
voltage. Only a competent electrician should carry out the electrical
installation. Improper installation of the motor or the MVS may cause
equipment failure, serious injury or death. Follow this manual, the
National Electrical Code (NEC
GROUNDING AND BRANCH CIRCUIT PROTECTION
It is the responsibility of the user or person installing the MVS to
provide proper grounding and branch circuit protection according to
the National Electrical Code (NEC
SHORT CIRCUIT
The MVS is not short circuit proof. Therefore, after severe overload
or short circuit, the operation of the starter should be fully tested.
®
) and local safety codes.
®
) and local safety codes.
2
MVS
SERIES