Summary of Contents for PCB Piezotronics IMI SENSORS 699A05
Page 1
Model 699A05 4-20 mA Loop Calibrator Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-959-4464 24-hour SensorLine: 716-684-0001 Fax: 716-684-3823 E-mail: imi@pcb.com Web: www.imi-sensors.com...
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Model 699A05 4-20 Milliamp Loop Calibrator Operating Instructions Basic Keypad Operations EZ-Check™ Switch SOURCE/OFF/READ Switch Slide the SOURCE/OFF/READ Switch to SOURCE to SOURCE mode: Slide the switch to select from Hi and low range pre- output a mA signal and to do 2 - wire transmitter set values and the mid ranger (Dial) is selectable.
Model 699A05 Operating Instructions EZ-Check™ Switch The EZ-Check™ switch has three positions -- high, dial, and low. Its position is shown at the left edge of the display with “HI” and “LO” indicators. Neither indicator indicates the middle position. Use of the EZ-Check™ switch depends on mode. Source Modes: Slide the EZ-Check™...
Model 699A05 Operating Instructions Power and Measure Transmitter Mode Receiv er Transmitter Input + IN - REF +OUT- (Sensor) ocess Signal) mulat d Input) Typical 2-Wire Transmitter Pow er Supply 0 to 0 VDC The Model 699A05 supplies 15Volts or 24 Volts to the transmitter and displays the output in mA or % on the Model 699A05 display. In read mode press the EZ-Dial™...
Model 699A05 Operating Instructions Specifications General Specifications: (Unless otherwise indicated all specifications are rated from a nominal 23 °C, 70 % RH for 1 year from calibration) Operating Temperature Range -20 to 60 °C (-5 to 140 °F) Storage Temperature Range -30 to 60 °C (-22 to 140 °F) Relative Humidity Range 10 % ≤RH ≤90 % (0 to 35 °C), Non-condensing...