Front Leds - UR FOG FAST 01 2C Installation And Use Manual

Table of Contents

Advertisement

WARNING!! After fog emission and for few minutes, the nozzle is very hot. RISK OF
BURNS IF TOUCHED by bare hands.
11
IMPOSTAZIONE DEL TEMPO DI SPARO E DIREZIONE DEL FLUSSO DI NEBBIA
IF BLUE LED IS FLASHING, TOGETHER WITH A CONTINUOUS SOUND FROM THE BUZZER,
AN ANOMALY IS DETECTED. SEE PARAGRAPH 16 "RESET FROM FAULT CONDITION".
9
FOG FLOW DIRECTION
To ensure the right direction to fog flow, it is recommended to insert a screwdriver of the
diameter of the hole and, without forcing, orient the nozzle in the correct direction.
This allows you to clearly see the direction and keep it in place while tightening.
To screw and unscrew the nozzle, you should use a pair of pliers in good condition, to avoid
damaging the plating.
Do not overscrew the nozzle, it is sufficient that the Teflon nozzle does not move.
Do not flow directly on objects or walls less than 2 meters away or to the floor if it is
installed at a height lower than 2.50 meters. During first two shots, teflon sphere settles, so
it is needed to tighten it again.
Remember, it is necessary to connect all three outputs to an alarm central or an electronic
panel that can see all those information in real time and take proper action.
In order to avoid accidental activation with subsequent fog emission, the inputs are in
"negative security", for this reason the disconnection of a wire does not cause activation.
So it is necessary to check carefully the reliability of connections and protect the cables to
the control panel to avoid the risk of accidental damages.
BLUE LED
When on: it means that the machine is armed and ready to shoot, if the heater has
reached the working temperature.
When flashing: means that something is wrong.
RED LED
When on: means that at least one cylinder is empty.
See paragraph 13 "Cylinders exchange and reset"
GREEN LED
When on: Fast 01 2C is hot and ready for fog emission.
When flashing: means that the heating process is in progress.
See paragraph 15 "Faults and possible solutions"
Fast 01 is not ready to shoot.

Advertisement

Table of Contents
loading

Table of Contents