Technical Specifications; Mains Power - UR FOG FAST 01 2C Installation And Use Manual

Table of Contents

Advertisement

06

TECHNICAL SPECIFICATIONS

* Industrial standard as from other
manufacturers
Weight without tanks
Max fog emitted in a single shot
Max fog emitted with full cylinders
Fog tanks capacity
Work time without mains power
Max power on heating system
Average power consumption during heating process
Heating time
Max consumption in steady state
Power consumption at 12V
Average batteries lifetime
Door tamper
Anti-tear off and anti-shift
The "empty" signal does not mean only that the cylinder is empty,
but also warns that the system is in reserve.
For this reason is very important to make the "reset" only when you actually
exchange the cylinder or you will lose the seconds counting. (See paragraph 13)
WARNING:
-
Loosened ferrule can cause dropping
-
Do not disconnect the machine immediately after the shot
-
Change batteries every year
-
Change the cylinder as soon as the "empty" signal appears
6
FAST 01 2C
22 Kg
1200 m
3
2400 m
3
2 x 600 ml
about 2,5 hours
2 X 300 w
540 W
about 2,5 hours
60 W
500 mA while shooting
12 months with 10 shots
Tamper screw
Accelerometer
60 mA in stand by

Advertisement

Table of Contents