The value in the first column indicates the volume of the room to be protected, with respective seconds of emission reported
in the second column. The value in m³ varies depending on the density to be obtained.
Within the second column, the first value allows to get the maximum density recommended to ensure the absence of any
residual, while with the second value you get minimum recommended visibility of according to the standard CENELEC,
whereas a higher visibility would make the fog superfluous. In places where a little residual causes no problems, it is
possible to increase the shooting time.
Please note that the higher the fog released, the more the time required to recover visibility. High levels of fog,
over recommended limits, can leave residual. Any residual generally disappears in 24/48 hours without intervention,
otherwise, it is sufficient a damp rag to clean. If you want to get a visibility of one meter after 60 seconds as required by
standards, which is used as a reference by all manufacturers of Fog Cannons, the number of shooting seconds must be
reduced by half.
12
CONNECTION EXAMPLES
The diagrams and examples below are intended to provide only for a "better understanding" of the operation
of the inputs / outputs. None of the diagrams below represents the "single scheme to perform" as, in respect of the
reference standard, there are specific indications and only using all inputs and outputs on the PCB it is possible to abide by
the standard.
For a connection in "anti-robbery mode" it's necessary a careful evaluation of the risks by a security consultant.
A
Example of connection FAST 01 2C inputs with outputs of a central antitheft
B
Example of connection of the FAST 01 2C outputs to drive LEDs and / or relays
C
Example of connection of the FAST 01 2C outputs with inputs of an antitheft normally opened with diods
needed only with some equipments.
D
Example of connection of the FAST 01 2C outputs with balanced inputs of an antitheft
E
Example of connection of the FAST 01 2C outputs with relay board
A - Example of connection FAST 01 2C inputs with outputs of a central antitheft
OC NPN OUT ON/OFF
+ INTERNAL SIREN
CENTRAL ALARM
11
+
+ 12V
GND
ARM
SHOOT
GND
+ 12V OUT
FAST