Schedule Screen: Example - Daikin Altherma 3 H F User Reference Manual

Hide thumbs Also See for Altherma 3 H F:
Table of Contents

Advertisement

Possible schedules
The table contains the following information:
▪ Schedule/Control: This column shows you where you can
consult the currently selected schedule for the specific control. If
needed, you can:
▪ Select another schedule. See
use" [ 4  14].
currently want to
▪ Program your own schedule. See
Example" [ 4  15].
▪ Predefined
schedules:
Number
schedules in the system for the specific control. If needed, you
can program your own schedule.
▪ Activation screen: For most controls, a schedule is only effective
if it activated in its corresponding activation screen. This entry
shows you where to activate it.
▪ Possible actions: Actions you can use when programming a
schedule. For most schedules, you can program up to 6 actions
per day.
Schedule/Control
[1.2] Room > Heating
Predefined schedules: 3
schedule
Activation screen: [1.1] Schedule
Schedule for the desired
Possible actions: Temperatures within
room temperature in
range.
heating mode.
[2.2] Main zone >
Predefined schedules: 3
Heating schedule
Activation screen: [2.1] Schedule
Schedule for the desired
Possible actions:
leaving water temperature
▪ In case of weather-dependent: Shift
for the main zone in
temperatures within range.
heating mode.
▪ Otherwise:
range
[3.2] Additional zone >
Predefined schedules: 1
Heating schedule
Activation screen: [3.1] Schedule
Schedule for when the
Possible actions:
system is allowed to heat
▪ Off: When the system is NOT
up the additional zone in
allowed to heat up the additional
heating mode.
zone.
▪ On: When the system is allowed to
heat up the additional zone.
[5.5] Tank > Schedule
Predefined schedules: 1
Schedule for the domestic
Activation screen: Not applicable. This
hot water tank
schedule is automatically activated if the
temperature for your
DHW mode is one of the following:
normal domestic hot water
▪ Schedule only
needs.
▪ Schedule + reheat
Possible actions:
▪ Comfort: When to start heating the
tank to the user-defined preset value
[5.2] Comfort setpoint.
▪ Eco: When to start heating the tank to
the user-defined preset value [5.3]
Eco setpoint.
▪ Stop: When to stop heating the tank,
even if the desired tank temperature
is not reached yet.
Note: In Schedule + reheat mode,
the system also takes the user-defined
preset value [5.4] Reheat setpoint
into account.
EAVZ16S18+23DA6V(7)+9W
Daikin Altherma 3 H F
4P556076-1A – 2021.09
"To select which schedule you
"4.7.4  Schedule screen:
of
available
predefined
Description
Temperatures
within
Schedule/Control
[7.4.2] User settings >
Predefined schedules: 1
Quiet > Schedule
Activation screen: [7.4.1] Activation
(only available to installers).
Schedule for when the
unit has to use which quiet
Possible actions: You can use the
mode level.
following system-defined preset values:
▪ Quiet
▪ More quiet
▪ Most quiet
See
[7.5.4] User settings >
Predefined schedules: 1
Electricity price >
Activation screen: Not applicable
Schedule
Possible actions: You can use the
Schedule for when a
following system-defined preset values:
certain electricity tariff is
▪ High
valid.
▪ Medium
▪ Low
See
prices" [ 4  13].
4.7.4

Schedule screen: Example

This example shows how to set a room temperature schedule in
heating mode for the main zone.
INFORMATION
The procedures to program other schedules are similar.
To program the schedule: overview
Example: You want to program the following schedule:
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Prerequisite: The room temperature schedule is only available if
room thermostat control is active. If leaving water temperature
control is active, you can program the main zone schedule instead.
1 Go to the schedule.
2 (optional) Clear the content of the whole week schedule or the
content of a selected day schedule.
3 Program the schedule for Monday.
4 Copy the schedule to the other weekdays.
5 Program the schedule for Saturday and copy it to Sunday.
6 Give the schedule a name.
To go to the schedule
1 Go to [1.1]: Room > Schedule.
2 Set scheduling to Yes.
3 Go to [1.2]: Room > Heating schedule.
To clear the content of the week schedule
1 Select the name of the current schedule.
User defined 1
Mon
Tue
Wed
Thu
Fri
Sat
Sun
4 Operation
Description
mode" [ 4  12].
"About quiet
"4.7.2 Setting the energy
User reference guide
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eavz16s18da6v7Eavz16s23da6v7Eavz16s18da9wEavz16s23da9w

Table of Contents