Function Table Of Ic - Sharp CD-BA300 Service Manual

Mini component system
Hide thumbs Also See for CD-BA300:
Table of Contents

Advertisement

IC1 VHiLC78645E-1: CD Servo (LC78645E) (1/2)
Terminal Name Input/Output Setting in Reset
Pin No.
1
SLC0
2
SLCIST
3
EFMIN
4
RF
5
RFVDD
6
RFVSS
7
FIN1
8
FIN2
9
TIN1
10
TIN2
11
VREF
12
REFI
13*
FE
14
TEC
15*
TE
16*
RFMON
17
JITTC
18
ADAVDD
19
ADAVSS
20
TD0
OUtput
21
FD0
22
SPD0
23
SLD0
24*
GPDAC
25
CONT4
Input/Output
26
CONT5
Input/Output
27*
SBCK/CONT6
Input/Output
28
SBCK/FG
29*
DEFECT
30*
V/*P
31*
FSEQ
32*
MONI1
33*
MONI2
34*
MONI3
35*
MONI4
36*
MONI5
37
VSS
38
VDD
39
DOUT
40
TEST
41
LVDD
42
LCH0
43
LVSS
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
All manuals and user guides at all-guides.com

FUNCTION TABLE OF IC

Output
For slice level
Input
Input
Output
RF signal monitor terminal.
RF power terminal.
RF earth terminal. To be connected to 0V.
Input
A+C signal input terminal.
Input
B+D signal input terminal.
Input
E signal input terminal.
Input
F signal input terminal.
Output
RFVDD/2
VREF voltage output terminal.
Input
Reference supply setting terminal.
Output
ZHI
FE signal monitor terminal.
Output
LPF capacitor connection terminal for TE signal.
Output
ZHI
TE signal monitor terminal.
Output
ZHI
RF internal signal monitor terminal.
Capacitor connection terminal for jitter detection.
Power terminal for servo A/D, D/A.
Earth terminal for serve A/D, D/A. To be connected to 0V.
ADAVDD/2
Output terminal for tracking control. D/A output.
Output
ADAVDD/2
Output terminal for focus control. D/A output.
Output
ADAVDD/2
Output terminal for spindle control. D/A output.
Output
ADAVDD/2
Output terminal for sled control. D/A output.
Output
ADAVDD/2
Servo D/A general-purpose output terminal.
Input Mode
General-purpose I/O terminal 4.
Input Mode
General-purpose I/O terminal 5.
Input Mode
General-purpose I/O terminal 6 or
Subcode reading clock input terminal.
Input
Subcode reading clock input terminal/FG signal input terminal/external
emphasis setting terminal. Terminal functions are set by commands. When
not used, connect to 0V.
Output
L
Defect terminal.
Output
H
Auto switching monitor output terminal for rough servo phase control. "H":
rough servo, "L": phase servo.
Output
L
Sync signal detection output terminal.
The status changes to "H" when the sync signal detected in EFM and the
sync signal of internal generation are identified.
Output
L
Internal signal monitor terminal 1.
Output
L
Internal signal monitor terminal 2.
Output
L
Internal signal monitor terminal 3.
Output
L
Internal signal monitor terminal 4.
Output
L
Internal signal monitor terminal 5.
Digital system earth terminal. To be connected to 0V.
Digital system power terminal.
Output
L
Digital OUT output terminal. (EIAJ format)
Input
L
Input terminal for test. To be connected to 0V.
Left channel
Output
LVDD/2
D/A converter
Function
Control output.
Resistor connection terminal for SLCO output current setting.
control.
RF signal input terminal.
Power supply for Left channel.
Left channel output.
GND for Left channel. Must be connected to 0V.
– 45 –
CD-BA300
Controlled by commands from the
microcomputer. When not used, set
them as input terminals and connect
to 0V, or set them as output
terminals and leave open.

Advertisement

Table of Contents
loading

Table of Contents