Stihl RMI 522 C Instruction Manual page 36

Hide thumbs Also See for RMI 522 C:
Table of Contents

Advertisement

Thread a grommet (1) onto each of the two
wire ends (2).
1 Fold open the left clamping lever (1).
2 Insert the stripped wire end (2) into the
terminal block as far as it will go.
3 Close the clamping lever (1).
34
Strip the right wire end (1) to the specified
length X using a suitable tool and twist the
wire strands.
X = 10-12 mm
1 Fold open the right clamping lever (1).
2 Insert the stripped wire end (2) into the
terminal block as far as it will go.
3 Close the clamping lever (1).
Fit the grommets over the terminal blocks.
Check the seating of the wire ends in the
terminal block: the two wire ends must be
firmly fastened.
● Close the panel. (
9.2)
Close the cover of the cable duct (1).
● After completing this installation
work, press the OK button.