Advertisement

4
Sets the Temperature report interval
(in minutes)
5
Sets the temperature offset
Use this parameter to calibrate the
temperature sensor if the default value
is not accurate relative to other
thermometers.
Specifications
Power
Z-Wave Frequency
Z-Wave Range
Z-Wave Data Rate
Operating Temp Range
Motion Sensor Range
Motion Sensor Coverage
Temperature Accuracy
Temperature Resolution
Light Sensor Range
Dimensions
Certifications
Warranty
HomeSeer warrants to the original purchaser that this product, for the warranty period, will be free from material defects and workmanship. This
warranty is subject to proper installation and operation of the product. HomeSeer's sole obligation, under this warranty, is to repair, replace or correct
any defect that was present at the time of delivery. This warranty does not extend to consequential or incidental damage to other products that may be
used with this product. Warranty claims must be submitted in writing directly to HomeSeer by emailing
Limited 1 year from date of purchase
FCC statements:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such
modifications or changes could void the user's authority to operate the equipment.
This product employs or practices certain features and/or methods of the following U.S. Patents: U.S. Patent Nos.6,891,838, 6,914,893 and 7,103,511.
1
Possible values: 1-255
1
Possible values: (-128) to (+127)
The value is in tenths of degrees Fahrenheit. The temperature reading can be
adjusted by -12.8F to +12.7F. A value of 1 will adjust the temperature reading by
+0.1F. A value of -5 will adjust the temperature by -0.5F. A value of 123 will adjust
the temperature by +12.3F.
120VAC / 60 Hz, 1W
908 / 916 MHz (US/CAN)
300 feet minimum line of sight
9.6Kbps, 40Kbps, 100Kbps
-20ºC to 80ºC
12ft
90º
+/-2.0C (-20C to 80C)
0.1C
0-10,000 LUX
3.25"H x 1.9"W x 1.9"D
ETL (US, Canada), FCC/IC, Z-Wave Plus