Color command
turns RGB LED on to a specific color
HomeSeer Compatibility
Your new HomeSeer sensor is Z-Wave certified and is ready to be used with a wide variety of home automation hubs and controllers. All features are
fully supported by HomeSeer systems but some
another brand of controller, be sure to check with that company to determine compatibility.
Advanced Features
Your new HomeSeer sensor includes advanced features that may be accessed with HomeSeer and other systems.
Temperature Reporting
HSM200 reports a temperature value to the hub. By default, this report happens every 60 minutes but the report interval may be adjusted from 1-255
minutes using Z-Wave parameters (see below).
Luminance Reporting
HSM200 reports a luminance (light level) value to the hub. By default this report happens every 60 minutes but the report interval may be adjusted
from 1-255 minutes using Z-Wave parameters (see below).
RGB LED Indicator
The color of HSM200's LED indicator may be controlled with Z-Wave COLOR CONTROL CLASS commands from the hub.
Non-HomeSeer Compatibility
Most non-HomeSeer hubs will recognize HSM200 as a BINARY sensor with ON (for motion) and OFF (for no motion) status. Temperature and
Luminance reports may or may not be detected. If the hub does not support the Z-Wave COLOR CONTROL command class, it won't be able to
change the RGB LED indicator. Be sure to check with your non-HomeSeer hub manufacturer for more information about compatibility.
Attention SmartThings users
A special
device handler
is required to enable your hub to use the advanced features of this switch. Information about installing this may be found at:
https://docs.homeseer.com/display/HSPRODKB/SmartThings
Z-Wave SmartStart
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR Code* with a controller providing SmartStart inclusion.
No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.
*QR Code is located on the back of the HSM200 unit.
Interoperability
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within
the network will act as repeaters regardless of vendor to increase reliability of the network.
Z-Wave Parameters
Use the parameters below to adjust HSM200 configuration settings:
Parameter
Description
1
Sets the time (in minutes) between
when an ON command is sent and an
OFF command is sent
2
Sets a the specific dim level that's sent
to all GROUP 2 association nodes
when motion is sensed
3
Sets the Luminance report interval (in
minutes)
Advanced Features
(see below) may not be fully supported by other controllers. If you're using
Bytes
Value
1
Possible values: 0-127
1-127 = ON and OFF commands are sent
0 = ON commands are sent but OFF commands are never sent
1
Possible values: 0*, 1-99, -1
0 = Sends OFF command (not recommended)
1-99 = Sends a DIM command
-1 = Sends an ON command
1
Possible values: 1-255
Default
10
-1