Pcb Display(18/24/60 K Model Only) - LG A8UW54GFA0 Installation Manual

Hide thumbs Also See for A8UW54GFA0:
Table of Contents

Advertisement

PCB Display(18/24/60 k Model Only)

It is useful to check the cycle data without LGMV.
Operating Method
Whenever you push the Tact Switch, the cycle information will be shown as below.
h After 1 page is displayed, subsequently 2 page is displayed.
Tact S/W
18/24/60 k
1 time
2 time
3 time
Discharge Temp.
4 time
Cond Out Temp.
5 time
6 time
ODU Air Temp.
7 time
8 time
9 time
10 time
DC Link Voltage
18 k
24 k
!
WARNING
When you push the Tact Switch, use the material non-conducting electricity.
Item
Low Pressure
Hi Pressure
Suction Temp.
Current
Voltage
Comp Hz
TACT_SW
TACT_SW
Display
Example
1 page
890 kpa
2 900 kpa
85 °C
-10 °C
-10 °C
-10 °C
15 A
230 V
100 Hz
230 V
Only 60 k
2 page
'LP'
' 89'
'HP'
'290'
'DS'
' 85'
'CS'
'-10'
'SS'
'-10'
'AS'
'-10'
'A'
' 15'
'V'
'230'
'F'
'100'
'dc'
'230'
TACT-SW1
Installation Manual 53
Function

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents