JACK CONTROL HYDRAULIC SWITCH
NEUTRAL POSITION
EXTEND
POSITION
TANK
To prime the hand pump, it will be necessary to remove a
hose from the cap end of the synchronizing cylinder and
place the hose in a bucket.
IMPORTANT: DO NOT ALLOW THE FLUID LEVEL IN
THE TANK TO LOWER MORE THAN 1 INCH BEFORE
ADDING FLUID.

MAINTENANCE

PRIMING THE HAND PUMP
OPERATING
MOTION
HAND PUMP
HANDLE
Move the room control hydraulic switch to "UP". Make sure
the tank is at least half full. Pump the hand pump until a
healthy flow of fluid comes from the hose.
Reattach the hose and retry the hand pump. Repeat the
procedure if the hand pump does not move the room.
CAP END
SYNCHRONIZING CYLINDER
REMOVE THIS HOSE
AND PLACE IN A BUCKET