Advertisement

Quick Links

SeaLINK+4.VC
User Manual | 2407
1
© Sealevel Systems, Inc.
2407 Manual | SL9174 6/2021

Advertisement

Table of Contents
loading

Summary of Contents for SeaLevel SeaLINK+4.VC

  • Page 1 SeaLINK+4.VC User Manual | 2407 © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 2: Table Of Contents

    APPENDIX C – ELECTRICAL INTERFACE ......................16 APPENDIX D – ASYNCHRONOUS COMMUNICATIONS .................. 17 APPENDIX E – SILK SCREEN - 2407 PCB ......................18 APPENDIX F – COMPLIANCE NOTICES ......................19 WARRANTY ................................ 20 © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 3: Introduction

    Introduction The Sealevel Systems SeaLINK+4.VC (Item# 2407) is a USB device that equips the PC with four RS-232 or RS-485 Asynchronous serial ports. The SeaLINK+4.VC supports RS-232 data rates up to 115.2K bps and RS-485 data rates up to 921.6K bps. The box does not need to be opened nor are there any dipswitches to set.
  • Page 4 Other Sealevel USB Serial I/O Product Family Model # Part # Description SeaLINK+232 2101 - 1-Port RS-232 DB25 SeaLINK+232 2105 - 1-Port RS-232 DB9 SeaLINK+485 2102 - 1-Port RS-422/485/530 DB25 SeaLINK+232I 2103 - 1-Port Isolated RS-232 DB25 SeaLINK+485I 2104 - 1-Port Isolated RS-422/485/530 DB25...
  • Page 5: Before You Get Started

    Before You Get Started What’s Included The SeaLINK+4.VC is shipped with the following items. If any of these items is missing or damaged, please contact Sealevel for replacement. • Item# 2407 – SeaLINK+4.VC USB 8-Port Serial Device • Item# CA179 – 72” USB ‘A’ to ‘B’ Device Cable •...
  • Page 6 Preconfigured for use with the SeaLINK+4.VC, this modular adapter converts the RJ45 RS-232 pinout from the SeaLINK+4.VC to a DB9 male RS-232 serial port. Standard CAT5 patch cables can be used to extend the serial port up to 50 feet away from the SeaLINK+4.VC.
  • Page 7: Software Installation Instructions

    An uninstall option is included to remove the driver and all registry/INI file entries from your system. 6. Proceed with the physical installation of your SeaLINK USB serial adapter. Windows NT is not USB aware and thus cannot support this device. © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 8: Physical Installation

    You should see one or more “New Hardware Found” windows, indicating the actual device being created. The installation will repeat twice for each COM port (a total of 8 times on the SeaLINK+4.VC). This is a limitation in the way Windows installs external serial devices.
  • Page 9: Technical Description

    Technical Description The SeaLINK+4.VC utilizes four USB UARTs. These chips feature programmable baud rate, data format, 128 byte Dual Port TX Buffer, and 384 byte Dual Port RX Buffer. The transceivers support data rates up to 921.6K bps. Connector Pin Assignments (RJ45)
  • Page 10 Configured for 24VDC input power using a 1.3mm DC jack Optional RJ45 to DB9 RS-232 Adapter Preconfigured for use with Sealevel USB RJ45-enabled serial adapters, the RJ45 to DB9 modular adapter (item# RJ9P-232) converts the RJ45 RS-232 pin out to a DB9 male RS-232 serial port. Standard CAT5 patch cables can be used to extend the serial port up to 50 feet away from the RJ45 port.
  • Page 11 ECHNICAL ESCRIPTION RS-485 Biasing and Termination 120W termination resistor always present between Data+ and Data- 510W Biasing pull-up resistors on Data+ 510W Biasing pull-down resistors on Data- © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 12: Electrical Characteristics

    Housed in rugged, attractive plastic enclosure • Integrates transmit and receive LED indicators on each port • High-retention USB type “B” connector prevents accidental disconnection of USB cable • Powered by USB connection © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 13: Specifications

    1.7” (4.32 cm) Manufacturing All Sealevel Systems Printed Circuit boards are built to UL 94V0 rating and are 100% electrically tested. These printed circuit boards are solder mask over bare copper or solder mask over tin nickel. © Sealevel Systems, Inc.
  • Page 14: Appendix A - Troubleshooting

    Details on loopback plugs are included within WinSSD. Contact Sealevel Systems if you need further assistance. 4. When testing the SeaLINK+4.VC in loopback mode, you should see both the TD and RD echoed as data on the screen. The loopback test first transmits a HEX pattern, 55AA, and then an ASCII string of data.
  • Page 15: Appendix B - How To Get Assistance

    When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics. Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
  • Page 16: Appendix C - Electrical Interface

    The RS-232 and the EIA/TIA-574 specification define two types of interface circuits, Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment (DCE). The SeaLINK+4.VC is a DTE device. RS-485 RS-485 is backwardly compatible with RS-422; however, it is optimized for party-line or multi-drop applications.
  • Page 17: Appendix D - Asynchronous Communications

    The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e., 9600, N, 8, 1). © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 18: Appendix E - Silk Screen - 2407 Pcb

    Appendix E – Silk Screen - 2407 PCB © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 19: Appendix F - Compliance Notices

    Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives. © Sealevel Systems, Inc. 2407 Manual | SL9174 6/2021...
  • Page 20: Warranty

    Sealevel's commitment to providing the best I/O solutions is reflected in the Lifetime Warranty that is standard on all Sealevel manufactured I/O products. We are able to offer this warranty due to our control of manufacturing quality and the historically high reliability of our products in the field. Sealevel products are designed and manufactured at its Liberty, South Carolina facility, allowing direct control over product development, production, burn-in and testing.

This manual is also suitable for:

2407