Download Print this page

Examples Of Ways To Connect Sensors - SECO-LARM Enforcer Sensor E-964-D390Q Manual

Twin photobeam detectors
Hide thumbs Also See for Enforcer Sensor E-964-D390Q:

Advertisement

Fig. 9: Examples of Possible Ways To Connect One or More Sensors
Example connection 1 - Standard
Transmitter
Receiver
Example connection 2 - Dual Sensors, Separate Channels
Transmitter
Transmitter
Receiver
Example connection 3 - In-line Single Channel
Transmitter
Transmitter
Receiver
Example connection 4 - Two stacked
Tx
Rx
Rx
Tx
Control panel
(12VDC)
}
Power
}
Alarm signal
Control panel
(12VDC)
}
Power
}
Alarm (ch. 1)
}
Alarm (ch. 2)
Receiver
Control panel
(12VDC)
}
Power
}
Alarm signal
Receiver
}
Power
}
Alarm signal
6
Selectable 4-channel beam frequency (For E-964-D390Q model only)
The sensor beam frequency can be set at different levels on-site to avoid interference from other twin
photobeam sensors nearby. Useful during mutliple sensor applications as shown below. To select
between four different beam frequencies, adjust the beam channel switch of the transmitter side and
receiver side. See fig. 1 for switch location and table 2 for switch position.
Important
– The transmitter and receiver sensor pair must be set with the same frequency.
Table 2: Beam Frequency Selection Chart (For E-964-D390Q model only)
CH3
Frequency channel
CH1
CH2
Switch position
1 2
1 2
1 2
Multiple sensor sample applications ( For E-964-D390Q model only)
1. Single pair multiple layer application.
Sensor #1
Tx
Rx
Ch1
Ch1
Sensor #2
Tx
Rx
Ch2
Ch2
Sensor #3
Tx
Rx
Ch3
Ch3
Sensor #4
Tx
Rx
Ch4
Ch4
2. Long distance series application.
Sensor #1
Sensor #2
Tx
Rx
Rx
Ch1
Ch1
Ch2
CH4
1 2
Sensor #3
Sensor #4
Tx
Tx
Rx
Rx
Ch2
Ch3
Ch4
Ch3
7
Tx
Ch4

Advertisement