CASH VALVE™ TYPES K-10 AND K-15 BACK PRESSURE VALVES
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
OPERATING INSTRUCTIONS
Adjusting the Delivery Pressure
The regulator's delivery pressure setting is
adjusted by turning the adjusting screw (2) at
the top of the spring chamber (6) after removing
the adjusting screw cap (1) and loosening the
adjusting screw lock nut (3). To obtain a higher
pressure setting, turn the adjusting screw
clock-wise (into the spring chamber). To lower
the pressure setting, turn the adjusting screw
counter-clockwise (out of the spring chamber).
Tighten the adjusting screw lock nut after the
adjustment has been made and install the
closing cap.

MAINTENANCE INSTRUCTIONS

The following procedures are provided for
servicing the K-10 and K-15 backpressure relief
valves. All repair parts can easily be installed
without removing the valve from the line.
CAUTION
Before attempting to replace any spare parts, be
sure to shut off all pressure connections to the
valve. With the valve closed, however, system
pressure could still be locked between the
shut-off valve and the inlet and/or outlet sides of
the relief valve. Before proceeding with the valve
service, be certain to relieve the pressure from
BOTH sides of the valve.
Refer to the K-15 cut away view for parts
and identification.
Servicing the Pressure Spring (7), Valve
O-rings (11 and 12), Valve Pusher Stem (13)
and Piston (14).
1. Unscrew the adjusting screw cap (1). Inspect
and if necessary, replace the cap O-ring (4).
2. Loosen the lock nut (3) ¼ turn and turn
the adjusting screw (2) counter-clockwise
until the pressure spring (7) is no longer
under tension.
NOTE
When installing the adjusting screw during
reassembly, turn the screw clockwise until the lock
nut touches the spring chamber. When the valve is
placed in service, the pressure setting should be very
close to the original setting.

TYPICAL INSTALLATIONS

FIGURE 1
TYPICAL HOOKUP AS PUMP BY-PASS
To Tank
From Tank
FIGURE 2
TYPICAL TYPES K-10 OR K-15 INSTALLED AT THE END OF PUMPING CIRCUIT TO MAINTAIN CIRCULATION
THROUGH ENTIRE LOOP
Return
Suction
K-10 SPRING RANGES
Size, in.
¼, ⅜
15-30
½, ¾, 1, 1
15-75
/
1
4
K-15 SPRING RANGES
Size, in.
¼, ⅜
25-75
½, ¾
-
TYPE K-10
OR K-15
Return Line
Pump
Suction
Power Unit
Pump
Adjustment Range, psi
25-75
50-140
-
50-150
Adjustment Range, psi
20-150
100-300
25-150
20-200
Discharge from
Pump
TYPE K-10
OR K-15
Power Unit
100-300
200-600
100-300
200-600
150-800
600-1500
100-700
600-1500
2