Wiring Diagram - Mitsubishi Electric PKFY Series Technical & Service Manual

Hide thumbs Also See for PKFY Series:
Table of Contents

Advertisement

5

WIRING DIAGRAM

PKFY-P32VGM, PKFY-P40VGM, PKFY-P50VGM
Symbol
Indoor controller board
I.B
CN32
Connector
Remote switch
CN41
HA terminal-A
CN51
Centrally control
CN52
Remote indication
SW2
Switch
Capacity code
SW3
Mode selection
SW4
Model selection
ZNR
Varistor
X4
Aux.Relay (Fan motor)
FUSE
Fuse (6.3A)
F.C
Fan phase control
T
Transformer
MF
3 2
1
C1
I.B
CNT
(WHT)
FAN1
1 3
5
(WHT)
X4
F.C
X4
CN26
2 1
(RED)
(GRN)
ADDRESS
VANE
CN81
CN6V
6
5
4
3
2
1
8
7
6
5
4
8
MV
A.B
SW5
4
(RED)
220V
240V
3
ADDRESS
CN43
2
SW1
1
ON
(RED)
OFF
ADDRESS
1 2 3 4 5 6 7 8 910
CN82
SW14
SW12 SW11
SWC
0
0
0
CONNEC
1ST
3RD
2ND
-TION No.
DIGIT
DIGIT
DIGIT
Note
1.At servicing for outdoor unit,always follow the wiring diagram of outdoor unit.
2.Symbol[S] of TB5 is the shield wire connection.
3.Symbols used in wiring diagram above are,
4.The setting of the SW2 dip switches differs in the capacity for the detail,see the table below.
5.Please set the switch SW5 according to the power supply voltare.
Set SW5 to 240V side when the power supply is 230 and 240 volts.
When the power supply is 220 volts, set SW5 to 220V side.
OC179B
Name
Symbol
Thermistor
TH21
TH22
TH23
MF
C1
MV
TB2
TB5
LEV
CND
(RED)
FUSE
250V
6.3A
(WHT)
REMOTE
CENTRALLY
INDICATION
CONTROL
CN52
CN51
5
1
5
(RED)
SW2
ADDRESS
CN42
0N
3
2
1
4
3
2
1
0FF
1
2 3 4 5 6
See fig: 1
4
8
7
6
< 1 >
5
Models
4
3
PKFY-
ON
OFF
2
P32VGM
1
ON
PKFY-
OFF
P40VGM
The black square (
) indicates a switch position.
:terminal block,
:connecter.
Name
Room temperature detection
(0 /15 ,25 /5.4 )
Pipe temperature detection/Liquid
(0 /15 ,25 /5.4 )
Pipe temperature detection/Gas
(0 /15 ,25 /5.4 )
Fan motor (with inner thermostat)
Capacitor (fan motor)
Vane motor
Terminal
Power supply
block
Transmission
Linear expansion valve
AC220-240V
T
AC18.4V
1
3
1
3
CN3T
(RED)
LED4
LED3
LED1
ZNR
(WHT)
(WHT)
(WHT)
REMOTO
LEV
SWITCH
CN32
CN60
6
5
4
3
2
1
1
1
3
(BLK)
(WHT) (RED)
SW3
SW4
GAS
LIQUID
0N
CN29
CN21
0FF
2
1
2 1
1 2 3 4 5 6 7 8 910
2
3
4
1
6
TH23
TH22
LEV
SW2
SW3
ON
OFF
1 2 3 4 5 6
1 2 3 4 5
6
7
8
9
10
ON
OFF
1 2 3 4 5 6
1 2 3 4 5
6
7
8
9
10
9
Symbol
Name
Circuit board
A.B
SW1
Switch
Mode selection
SW5
Voltage selection
SW11
Address setting 1st digit
SW12
Address setting 2nd digit
SW14
Connection No.
SWC
Option selector
TO NEXT INDOOR UNIT
TB2
RED
L
BLU
N
GRN/YLW
CN2M
1
(BLU)
BLU
2
POWER SUPPLY
M-NET
BLU
~ 220-240V 50Hz
~ 220V 60Hz
LED2
LED5
TB5
S(SHIELD)
(RED)
M2
DRAIN
M1
CN50
1
5
4
3
2
1
HA
CN41
INTAKE
(WHT)
CN20
2
1
4
TH21
Models
SW2
ON
ON
PKFY-
OFF
OFF
P50VGM
1 2 3 4 5 6
1
PULL BOX
FUSE(15A)
BREAKER(15A)
TO OUTDOOR UNIT
BC CONTROLLER
REMOTE CONTROLLER
DC24-30V
SW3
2
3
4
5
6 7 8 910