MGSK-600
(MIANS VOLTAGE)
START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS
START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS
START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS
• Failure to comply with the following instructions may result in serious personal injury or property damage.
• Read and follow all instructions carefully (The complete Instruction Manual needs to be referred to for the complete correct
installation and setup process.)
• The gate opener is designed and tested to offer safe service, provided it is installed and operated in strict accordance with the
instructions in this quick reference guide.
Before you begin the installation (The complete Instruction Manual needs to be referred to for the complete correct installation
and setup process):
This product must be installed by a professional installer.
The installer must understand the following:
• The operation of the drive and potential hazards
• The operation of the manual emergency release mechanism
• The regular maintenance, inspection and care according to the standards
• The installer must instruct other uses on the safe operation of the gate opener
Please read the operating instructions and especially the precautions. The following symbols are placed in front of instructions to avoid
personal injury or damage to property. Read these instructions carefully.
Warning Symbols
The general warning symbol indicates a danger that can lead to injuries or death. In the text section, the general warning symbols are
used as described below.
DANGER Symbol
DANGER
Indicates an imminent
hazardous situation which, if not
avoided, will result in death or
serious injury.
Intended Use
The gate opener is exclusively designed and tested for the operation of smooth-running residential gates.
The maximum permissible gate size and the maximum weight must not be exceeded. The gate must open and close smoothly by hand.
Use the opener on gates which comply with the applicable standards and guidelines. Regional conditions of wind loads must be taken
into account when using door or gate panels. Observe the manufacturer's specifications regarding the combination of gate and opener.
Possible hazards within the meaning of AS/NZS 60335.1 in conjunction with AS/NZS 60335.2.103 are to be avoided by designing and
installing the gate according to the relevant instructions. This gate mechanism must be installed and operated in accordance with the
appropriate safety rules.
Improper Use
The construction of the gate opener is not designed for the operation of heavy-duty gates. It is not permitted on gates that travel with
incline/decline.
Any improper use of the gate opener could increase the risk of accidents. The manufacturer assumes no liability for such usage. With
this gate opener, automated gates must comply with the current, valid local standards, guidelines and regulations, AS/NZS 60335.1 in
conjunction with AS/NZS 60335.2.103.
Only Merlin genuine and approved accessories may be connected to the gate opener. Incorrect installation and/or failure to comply with
the following instructions may result in serious personal injury or damage to property.
QUICK REFERENCE GUIDE
MGSK600 / MGSK600-LV
MGSK-600-LV
(LOW VOLTAGE)
SAFETY INSTRUCTIONS - WARNING!
SAFETY INSTRUCTIONS - WARNING!
SAFETY INSTRUCTIONS - WARNING!
WARNING Symbol
WARNING
Indicates a potentially hazardous
situation which, if not avoided,
could result in death or serious
injury.
CAUTION Symbol
CAUTION
Indicates a potentially hazardous
situation which, if not avoided,
could result in minor or
moderate injury.
ST
ST
ST
ATTENTION Symbol
ATTENTION
Indicates practices not
related to personal injury.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Slide 600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Merlin Slide 600

  • Page 1 AS/NZS 60335.1 in conjunction with AS/NZS 60335.2.103. Only Merlin genuine and approved accessories may be connected to the gate opener. Incorrect installation and/or failure to comply with the following instructions may result in serious personal injury or damage to property.
  • Page 2 QUICK REFERENCE GUIDE STEPS 1-5 INSTALLATION Opener (MGS600 or Instruction MGS600-LV) Manual 4 x M8 x 40mm Take out each of the items included 4 m Slide Gate Rack 4 x M8 x 80mm Bolts with hexagon 2 x Release in the sales kit.
  • Page 3 QUICK REFERENCE GUIDE INSTALLING THE LIMIT SWITCH BRACKETS Position the limit switch brackets in the approximate open and close positions on the rack. Loosely attach the brackets to the rack. The magnets are marked "L" and "R". L positioned on the left of the rack, while R is positioned on the right of the rack when looking from inside the property.
  • Page 4 INSTALL ENTRAPMENT DEVICES THE PROTECTOR SYSTEM™ (IR BEAMS) (OPTIONAL) NOTE: Merlin strongly recommends that The Protector System™ (IR Beams) be installed on all gate openers. Compatible Protector System™ (IR Beams) are 772ANZ and GPS15 Monitored Safety Beams. The Protector System™ (IR Beams) can be configured to function differently when connected to IR1, IR2 or IR3 inputs.