Putting Into Operation; Tank Cleaning - Iarp VIC CREAMY User Instructions

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
Modello - Modèle - Model
Modell - Modelo
Fabbricante - Constructeur
Manufacturer - Hersteller
Fabricante
13.

PUTTING INTO OPERATION

If the cabinet has been sharply tilted while being sited or for mounting of
accessories, it must be left to stand for at least three hours before being started
to allow the lubricating oil to settle in the compressor.
Failure to do so can cause total destruction of the compressor refrigerating system.
Check that the voltage on the identification plate is the same as that of the
network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE
REFRIGERATOR WILL HAVE TO BE CONNECTED
IS TO BE PROTECTED BY A VERY SENSITIVE
DIFFERENTIAL SWITCH (Rc=16A,Dc=30mA); IT IS
ALSO TO BE LINKED TO THE GENERAL EARTHING PLANT.
Earthing is necessary and compulsory by law.
Absolutely never use reduction units, patch cords, adapters
or multiple socket outlets to connect the counter.
DIRECTLY connect the equipment to the mains.
The cable should be fully extended and located where it is unilikely to be struck, caught or
stepped on, away from water and the other liquids and heat sources and must
not be damaged. In case of breakage of the power cable of the cabinet, it must
be replaced by the manufacturer or by instruction it change of it.
Follow the manufacturer's instructions to install the unit, using qualified personnel
and complying with the electrical regulations for the specific country.
Incorrect installation may cause injury and damage; the manufacturer is not
liable for this.
The manufacturer disclaims all responsability for any damage to people or things
due to incorrect observance of this rule.
14.

TANK CLEANING

WARNING! TURN OFF POWER SUPPLY TO THE CABINET BY DISCONNECTING
THE POWER PLUG BEFORE CLEANING
If , however, the layer of frost on tank walls exceeds 4/5 mm in thickness, you should completely
defreeze the appliance as follows:
1.
Place the goods in special refrigerated containers, kept at the same temperature.
2.
Leave the doors open and begin the operation of tank washing when the tank temperature is
the same as the ambient temperature.
3.
Remove the internal draining plug and place under the body (if it's possible) a tray for water
discharging.
4.
Before cleaning the tank the inside temperature must be equal to the ambient temperatur.
5.
Proceed with washing and drying the internal chamber with a cloth using neutral PH detergent
and fresh water.
6.
Clean the dividers with a cloth, using neutral PH detergent, rinse and dry.
7.
Then plug the unit and wait till the appliance reaches the right temperature before filling it again.
Do not use any aggressive or abrasive cleaning agents.
Never use a water hose or a high-pressure jet to clean the cabinet.
WARNING! Do not use jet of water to clean the cabinet: electrical wiring
could be damaged.
WARNING! Never use mechanical devices or any other means to accelerate
the defrosting process, other than those recommended by the manufacturer.
VIC CREAMY
EPTA S.p.A. - Sede legale
Via Mecenate, 86 - 20138 Milano – Italy
Capitale € 68.515.000 - R.E.A./MI – 1730229
Registro delle Imprese e Cod.Fiscale n. 04160730968
Partita IVA 04160730968
2 4 / 6 8
PAGE
UM000551
N° DOC

Advertisement

Table of Contents
loading

Table of Contents