Step 5 - Finishing Touches; Care And Maintenance; Troubleshooting - Eaton ephesus Arena Series Installation Instructions Manual

Table of Contents

Advertisement

Installation Instructions - Arena Series
AFTER FINAL AIMING
1.
After aiming is complete, tighten all bolts and screws including the Allen bolt on side of Luminaire and mounting
hardware.
Hardware
Torque Value
Side Allen Bolt
20-30 ft-lbs
Mounting bolt/nut
35-45 ft-lbs
2.
Briefly turn the laser back on or re-check view through tube to verify that the luminaire aim did not shift during
tightening.
3.
Remove the aiming mount from the Luminaire and proceed to the next luminaire.
After aiming, verify that every luminaire is securely mounted, the hardware is fully tightened down, and that all safety
N
otee:
cables are in place.
Step 5 – Finishing Touches
To complete the installation, verify that all mounting, connection, and aiming work is finished.
Verify all electrical connections are tight and secured. The installer is responsible for the integrity of all connections.
Verify all bolts and screws are tightened and properly torqued.
Straighten up all cabling. Tie down all cables neatly. For all outdoor projects, use UV rated tie wraps and wire
management.

CARE AND MAINTENANCE

All luminaires are prepared with a powder-coated finish. The finish on exterior luminaires may weather over time, depending
on the environmental conditions at the installation site. Proper care of the luminaires will maintain their performance and
appearance.
Follow a regular maintenance schedule to retain optimal light output and thermal performance. Remove any dirt, leaves and
other foreign debris from the luminaire housing. Wipe the optical lenses with a clean, dry, cotton cloth to remove dust and
other contaminants. A non-abrasive polycarbonate cleanser may be used periodically.
Do NOT use any abrasives such as car wax, brass cleaners or other polishes or chemicals. These may scratch,
remove, or damage the protective coating, allowing moisture and pollutants to come into contact with the
aluminum, possibly discoloring or pitting the finish.

TROUBLESHOOTING

Before performing any work on the luminaire, shut off the power circuit, verify the power is off with a multimeter,
and wait 2 minutes before handling luminaire to avoid electrical shock. FAILURE TO FOLLOW THIS WARNING MAY
LEAD TO DEATH, SEVERE INJURY, OR PROPERTY DAMAGE.
Symptom
No light output
Fuse blows or circuit breaker trips Crossed wires or a supply wire is grounding
Troubleshooting Guide
14
EATON
IB528001EN
Possible Cause
Power is off.
Bad wire connection.
Control signal set to 0
out.
Improperly sized fuse or breaker
Installation instructions
WARNING
WARNING
Corrective Action
Check if circuit power is on.
Check input wiring connections.
Verify control signal
Check wiring connections.
Refer to Table 5

Hide quick links: