GENDRON 5148PDX User Manual

Bariatric acute care bed

Advertisement

Quick Links

USER MANUAL
Bariatric Acute Care Bed
Model 5148PDX & 5154PDX
Gendron Inc.
520 W. Mulberry Street –Suite 100
Bryan, Ohio 43506
www.gendroninc.com

Advertisement

Table of Contents
loading

Summary of Contents for GENDRON 5148PDX

  • Page 1 USER MANUAL Bariatric Acute Care Bed Model 5148PDX & 5154PDX Gendron Inc. 520 W. Mulberry Street –Suite 100 Bryan, Ohio 43506 www.gendroninc.com...
  • Page 3: Table Of Contents

    Table of Contents Parts Locator (Bed) Parts Locator (Power Drive System) Safety Notes (Bed and Power Drive System) Power Requirements Features (Bed and Power Drive System) Function & Basic Operation (Bed and Power Drive System) Assembly Instructions Bed and Power Drive System Controls Diagnostics &...
  • Page 4: Parts Locator (Bed)

    Parts Locator (Bed) PATIENT HELPER (OPTIONAL) HEADBOARD DECK EXTENSION-LEFT SIDERAIL FOOT-LEFT RELEASE SIDERAIL FOOTBOARD HEAD-RIGHT BRAKE/STEER DECK EXTENSION DECK EXTENSION PEDAL FOOT RIGHT...
  • Page 5: Parts Locator (Power Drive System)

    Parts Locator (Power Drive System) VARIABLE SPEED FORWARD/REVERSE SWITCH MOTOR MOTOR BRAKE ON/OFF SWITCH WHEEL BRAKE OVERRIDE LEVER POWER DRIVE BATTERY CHARGER POWER CORD POWER DRIVE BATTERY CHARGER Headboard...
  • Page 6: Safety Notes (Bed And Power Drive System)

    Safety Notes (Bed) Failure to observe these safety precautions may result in personal injury or mechanical failure. Read all instructions carefully before using the bed. When a patient is left unattended or while transporting a patient it is recommended that the siderails are raised. When raising the siderails make sure it is completely raised and locked.
  • Page 7: Power Requirements

    Do not service this device without first unplugging the power cord and battery. Bed sections can move even with power cord unplugged because of backup battery. If service is required it is recommended that you contact Gendron customer service at 1-800-537-2521 or your local authorized Gendron dealer. Weight capacity: Never exceed the rated capacity of your bed (combined weight of user and items on bed.) Exceeding weight limit may...
  • Page 8 Unplug battery to prevent discharge during storage. Failure to do so will reduce battery life. Always allow head section to fully lower when using CPR release. Failure to do so may damage actuator. Disconnect AC power before unplugging any cables on the control module.
  • Page 9: Features (Bed And Power Drive System)

    - Construction: Constructed entirely of steel, solid frame, powder coat paint. - Bed deck: Adjustable to widths 39”, 48” (on 5148PDX bed) and 39”, 48” and 54” (on the 5154PDX bed). Length adjustable from 84” to 92” on both styles of bed.
  • Page 10 - Rotating scale display: Scale display rotates down to protect patient privacy while not in use. - Caregiver control panel: Allows caregiver access to bed controls and lockouts for patient pendant control. - Accessory sockets: One IV socket on each corner of bed. - IV Pole (optional –...
  • Page 11: Function & Basic Operation (Bed And Power Drive System)

    Function & Basic Operation (Bed) Patient Pendant Pendant control allows easy operation of bed controls. Press and hold button to operate each function. 1) Raise and lower head section 2) Raise and lower bed deck 3) Raise and lower knee section 4) Cardio chair/bed flat (lowers head, knee and returns bed to lowest height) 5) Trendelenburg/ reverse Trendelenburg...
  • Page 12 Function & Basic Operation (Power Drive System) On/Off Switch Forward Reverse Quick Disconnect...
  • Page 13 Function & Basic Operation (Power Drive System) Engage Power Drive 1. Ensure both Power Cords are unplugged and properly stored. 2. Using the Hand Pendent Bed Control, lower bed to completely Lowest Position. 3. Using Brake/Steer foot pedal, set casters in steer position. 4.
  • Page 14 Caregiver Controls Caregiver controls are located at the foot end of the bed, on the side opposite of the rotating scale display. Caregiver Controls...
  • Page 15 Battery Indicator: Red Light (charging), No Light (fully charged) Lockout control To lock/unlock a function from being used press and hold the up/down arrow button of the function to be locked/unlocked. A yellow LED is lit above the buttons of locked functions. Head/Knee/Bed/Tilt (trendelenburg/ reverse trendelenburg) Press and hold the button of the function desired + Cardio chair position...
  • Page 16 Central Brake/Steer Function The Brake/Steer pedals are located at each corner of the bed Neutral Position When positioning the bed in a small area place the Brake/Steer pedal in the neutral position (pedals level) to release the steer function and brakes.
  • Page 17 Push Handles The push handles are located at the head end of the bed, on the headboard, and are used to facilitate moving the bed. Caution: Do not move the bed using the side rails. Push Handles...
  • Page 18 Siderail Operation Siderails are located on each side of the bed. Siderails have a 2-position swing down operation. To raise siderail, grasp top section of rail and lift. Allow release pin to snap into the locked position. Caution: Make sure siderails are securely locked into position to prevent injury.
  • Page 19 CPR Release For emergency lowering of head section pull and hold the CPR release handle. The CPR release handle is located at the head end of the bed on both the left and right side. Caution: Always allow head section to fully lower when using CPR release.
  • Page 20 Using the deck extensions the bed width can be changed from 39” to 48” (5148PDX) and 39” to 48” to 54” (5154PDX). To adjust the side extensions pull the black knob that is at the end of each extension and move to the desired position.
  • Page 21 Foot Extension Using the foot extension, the bed length can be adjusted from 84” to 92”. To adjust the foot extension, pull the black knob that is at center of the extension (below the footboard) and move to the desired position. Caution: Gently push/pull on the extension to verify that it is locked in position.
  • Page 22 Battery backup Battery backup allows full use of bed functions when AC power is not available for a limited time. Caution: Disconnect battery to prevent discharge during storage. Failure to do so will reduce battery life. Caution: Recharging a fully discharged battery may take up to 24 hours. Battery cable is located at the head end of bed frame and plugs into the nurse call junction box.
  • Page 23 Low Profile Patient Helper (optional – not included) The patient helper is intended to help the patient raise his or her upper body. The patient helper handle may be raised or lowered by adjusting the strap. While the patient helper is not in use, the boom can be rotated 90 degrees in either direction and locked.
  • Page 24 IV Pole (optional – not included) IV pole may be used at any one of the (4) corners of the bed. Rotate the yellow release mechanism to raise or lower IV pole.
  • Page 25: Assembly Instructions

    Assembly Instructions Low Profile Patient Helper 1. Assemble patient helper frame to head end of bed frame using 4 bolts and locknuts. 2. Lower patient helper boom onto patient helper frame. Make sure release pin engages frame and holds boom rotation. 3.
  • Page 26 Headboard 1. Insert headboard mounting tubes into the square sockets at the head end of the bed as shown below. Mounting tube Socket...
  • Page 27 Footboard 1. Insert footboard mounting tubes into the square sockets at the foot end of the bed. 2. Connect the two electrical cables. Sockets Cables Mounting tubes Footboard Removal Caution: Disconnect the two electrical cables below the footboard before attempting to remove the footboard. Equipment damage may occur.
  • Page 28 Battery 1. Plug battery into nurse call junction. NURSE CALL BATTERY...
  • Page 29: Bed And Power Drive System Controls

    Bed Controls Linear actuators control head/knee section as well as bed movement. Control module controls all drive components. Battery provides backup power in case of power failure. Under bed light night light illuminates the area under the bed for patient safety. Handset (shown on page 9) gives patient access to bed controls.
  • Page 30 UNDER BED LIGHT NURSE CALL CONTROL MODULE Diagnostics & Repair (Bed)
  • Page 31: Diagnostics & Repair (Bed And Power Drive System)

    Problem Cause Solution ______________________________________________________________________ No Functions operate No power to unit Check power cord. Is it plugged into receptacle? Green Power-on light Electrical power cord not does not glow properly plugged into Check cord for breaks. control module Power cord plugged Check for power to receptacle.
  • Page 32 ______________________________________________________________________ Drive does not operate Batteries need charged Ensure batteries are charged. Switch not in ON position Switch will illuminate when power drive is on Short in directional control Turn ON/OFF switch to OFF switch then back to ON. Bed not is lowest position Lower bed to lowest position.
  • Page 33: Scale

    Scale The scale can be used to monitor the patient’s weight, change in weight and to alert the caregiver when the patient exits the bed. The scale display rotates down when not in use for patient privacy. The scale system is powered by the beds electrical system therefore no batteries are required.
  • Page 34 Bed Exit Alarm press to enable or disable alarm. Use the menu button to program the alarm parameters. The facility nurse call can be activated by the bed exit alarm if desired by using either the DB37 or 1/4” phono jack located at the head end of the bed.
  • Page 35 To edit scale system setup: Press Menu Use Up arrow to change menu selection Use Down arrow to toggle value Press Freeze to save changes or Weigh to exit without saving changes The parameters listed below can be changed through the Menu Bed Exit Alarm on 0-45% of patient weight in 5% increments.
  • Page 36: Inspection, Cleaning & Maintenance

    - Inspect patient helper frame and strap. If strap is worn replace immediately. - When you are satisfied that the bed is operating properly, instruct all personnel who may be involved in the bed operation. If problems are found, contact Gendron customer service at 800-537-2521 or your authorized Gendron dealer.
  • Page 37 Cleaning Warning: Before cleaning any portion of the bed, disconnect power cord from the wall outlet. Caution: Before using any cleaning product, test it on the underside of the bed. Never use any volatile or flammable fluid (thinner, gasoline, etc.) that could cause discoloration or deterioration. Use mild soap and water or a nonabrasive hospital-grade detergent disinfectant to clean the bed.
  • Page 38: Specifications

    Bed Weight: 710 pounds Note: All dimensions are approximate This bed meets FDA recommendations to reduce entrapment risk detailed in “Hospital Bed System Dimensional and Assessment Guidance to Reduce Entrapment” issued March 10, 2006 when used with Gendron mattress .14884-F & .14884-1F.
  • Page 39: Warranty

    Gendron, Inc. warrants the bed frame to be free from defects in materials and workmanship for a period of (5) years from date of purchase.

This manual is also suitable for:

5154pdx