6. Installer mode

To enter installer parameters please follow steps below. Please refer to parameters table description before any changes. Use
parameters. Use
or
for adjustements. Every change/selection confirm by
1
3 sec
Press and hold
simultanously for about 3 seconds to
DETAILED TABLE WITH ALL INSTALLER PARAMETERS:
dxx
d01
Temperature display accuracy
d02
Temperature offset
d03
Frost Protection setpoint temperature

6.1 DIP switches parameters

DIP switches are used to set chosen control algorithm. They are located under back cover of the thermostat (please refer to the picture below):
The position of the DIP switches determines the type of control algorithm:
1
ON
OFF
ON
OFF
PLEASE NOTE! TPI algorithm is recommended for underfloor heating. It can be adjusted between a low comfort level (6 CPH) and a higher
comfort level (9 CPH). „CPH" means cycles per hour and it relates to the frequency of the measurement cycles performed by thermostat.
* Function available only from firmware version 2.1
3 sec
3 sec
+
+
enter the installer mode.
Function
2
Cooling *
ON
Hysteresis +/- 0.25
ON
Hysteresis +/- 1.5
OFF
Hysteresis +/- 1.0
Hysteresis
OFF
+/- 0.5
button.
2
Use
parameters. Use
adjustements. Every change/selection
0.1°C or 0.5°C
+/- 3.0°C
5.0°C - 17.0°C
Heating
Default value
Hysteresis +/- 0.25
Hysteresis +/- 0.5
TPI 9 CPH
TPI 6 CPH
button to move through
button to move through
or
for
confirm by
button.
Parameter
0.5°C
0.0°C
5.0°C
9CPH
6CPH
1
Default
value
ON
Span
±0.25°C
TPI
2
15