Technical data

Voltage versions and electrical data

3N AC 400 V, 50/60 Hz, EL A01Z
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3N AC 400 V, 50/60 Hz, RH
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3N AC 400 V, 50/60 Hz, EH
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland
3 AC 230 V, 50/60 Hz, EL B04Z
Supply voltage
Frequency
Required fuse rating (on site)
Power rating
Connection cable, min. cross-section
Cable gland

Plumbing

Models with detergent drawer (DD)
Permitted flow pressure
Maximum intake rate
Cold water connection
(to be provided on site, male thread according to DIN 44991, flat seal)
Optional hard water connection, cold
(on-site external thread according to DIN 44991, flat seal)
Hot water connection (≤ 70 °C)
(on-site external thread according to DIN 44991, flat seal)
Length of inlet hoses supplied
en - PWM 514
3N AC 400V 50/60Hz
50/60 Hz
16 A
9,6 kW
2,5 mm²
3N AC 400V 50/60Hz
3N AC 400V 50/60Hz
3 AC 230V 50/60Hz
3 x ½" with ¾" threaded union
2 x ½" with ¾" threaded union (optional)
1 x ½" with ¾" threaded union
50/60 Hz
16 A
9,6 kW
2,5 mm²
50/60 Hz
16 A
2,3 kW
1,5 mm²
50/60 Hz
35 A
9,6 kW
4 mm²
1000 kPa
47,5 l/min
1,55 m
35