Ambient Conditions; Safety Clearances - SMA Sunny Island SIC50-MPT Installation Manual

Charge controller
Table of Contents

Advertisement

SMA Solar Technology AG
5.1.2 Ambient Conditions
• The mounting location and method must be suitable for the weight and dimensions.
• Mount on a solid surface.
• The mounting location must be accessible at all times.
• The charge controller must be easy to remove from the mounting location at any time.
• The ambient temperature should be between -25 °C and +60 °C to guarantee optimal
operation.
• Do not expose the charge controller to direct sunlight to avoid power losses due to overheating.
5.1.3 Safety Clearances
Observe the following safety clearances to walls, other devices or objects to ensure sufficient heat
dissipation.
Direction
Sides
Top
Bottom
Multiple charge controllers installed in areas with high ambient temperatures
If necessary, increase the clearances between the individual charge controllers. In
addition, make sure there is enough ventilation to ensure sufficient cooling of the charge
controller.
Installation Guide
Safety clearance
20 cm
30 cm
20 cm
Assembly
SIC50-IA-en-11
15