Wood Warm Air Heaters FH50ECP and FH100ECP INSTALLATION INSTRUCTIONS Please read carefully the precautions for use and the instructions for use before any installation and commissioning. Page 02/04/2019...
If the appliance is installed in a place where there are disabled people and / or accompanied by children, it must be installed with protections in accordance with the regulations in force. Never load more than 10 kg of log wood or briquettes for FH50ECP and 20Kg for FH100ECP, i.e. 50 and 100 kW.
Page 3
Diameter equal to or greater than the nozzle of the device and without section reductions. (Ø 153 mm for FH50ECP and Ø 200 mm for FH100ECP) • Do not add elbows with more than a 45 ° angle and raise the duct in this case by 1m per 45 °...
2.1 PACKAGING AND TRANSPORT: Hot air generators are shipped with plastic bubble wrap. The accessories are packed separately in cardboard packaging. Transport and unloading must be carried out with great care to avoid possible damage. Before accepting the packages, it is advisable to unpack the equipment in the presence of the carrier in order to ascertain the condition of the goods and therefore to avoid any dispute.
Page 5
This depression should be 2 mm WC after the pull key. It is therefore recommended for this result a vertical height of 5m for an FH50ECP and 6 to 7m for an FH100ECP. In order to stabilize the draft, it is necessary to install at the outlet of the Ø 153mm nozzle for FH50ECP and 200mm for FH100ECP, a tee fitted with a regulator flap.
Page 6
If you notice after several hours of use that smoke is coming out of the the sides of the loading hatch closed, the duct does not have enough draft. It must therefore be enhanced. It is imperative that the duct exceeds at least 50 cm the highest point of the roof called "ridge"...
Any load greater than the maximum load corresponding to the power of the device, i.e. 10 kg for FH50ECP and 20 kg for FH100ECP, irreparably implies overheating of the device in the short term, which causes damage: 1 - The crack in the refractory brickwork 2 - Deformation of the floor cross members which support the INOX floor grid.
Page 8
• Commissioning after briquetting - Load the appliance with wood or any other non-polluting solid fuel (for FH50ECP with a maximum of 10kg, for wood, which represents a combustion of 50KW / for FH100ECP with a maximum of 20Kg, for wood, which represents a combustion of 100Kw) - Connect the fan to the 240V + T electrical network.
2.7 EXPLODED VIEW OF THE UNIT: Smoke outlet Draft regulation key with pull key Group electro-fan Fairing exchanger heat Brickwork refractory Stainless steel grid Hopper ground air distribution Door of loading Drawer Room of collection of combustion Page 02/04/2019...
Page 10
2.8 DIMENSIONS: Model FH50ECP 180 mm 700 mm 1110 mm 1180 mm 780 mm 970 mm 620 mm Model FH100ECP 182 mm 900 mm 1286 mm 1790.50 mm 1340.50 mm 845 mm Page 02/04/2019...
Page 11
2.9 DESCRIPTION, CABINET OPERATION (OPTIONAL) AND DIAGRAM The fan regulation allows the fan to be started up at the set temperature (i.e. around 30 ° C). As soon as the thermal heating circuit is at this temperature, the fan will start up (inverter in winter position). When the appliance cools down, the fan will stop at the set temperature in order to prevent the circulation of fresh air during the mass heating cycle.
Page 12
270° At 50% power, i.e. around 150 ° C, you can reload the wood heater with fuel to develop the maximum power, i.e. 5 kg for the FH50ECP or 10 kg for the FH100ECP, of additional fuel. Page...