Download Print this page

Required Tools - ETC CueSystem Installation Manual

Relay interface

Advertisement

ETC Installation Guide
CueSystem Relay Interface
Installation Requirements
• Dry locations only
• 0–35°C (32–95°F) ambient temperature
• 30–90% non-condensing humidity
• The installation location must support the weight of the Relay Interface (2 kg [5.3 lb]) plus applicable
installation accessories and hardware.
Mount the Relay Interface
The CueSystem Relay Interface includes mounting hardware for four mounting options:
1. wall-mount: flat plate with slotted holes
2. pole-mount: flat mounting plate with round holes, two U-bolts, four washers, and four 3/8 inch nuts
3. C-clamp: L-shaped mounting hanger
4. desktop: four rubber feet and four M4x12 mm Phillips-head screws
The hardware also includes four M4x8 mm Phillips-head screws that can be used to install the wall-mount
plate, pole-mount plate, or C-clamp hanger.

Required Tools:

The following tools are required but not provided.
Wall-Mount: Phillips screwdriver and four each mounting bolts or screws and wall anchors
Pole-Mount: Phillips screwdriver, 9/16 inch nut driver or wrench, and pole with 50 mm (2 inch) outer
diameter
C-Clamp: Phillips screwdriver, C-clamp, and compatible wrench
Desktop: Phillips screwdriver
Wall-Mount
1. Using the Phillips screwdriver and the four
M4x8 mm screws, secure the wall-mount plate
to the back of the Relay Interface.
• The wall-mount plate has slotted holes.
2. Align the enclosure in its desired installation
location and mark, then pre-drill the four
mounting holes.
3. Install wall anchors as needed.
4. Align the driver to the mounting location and
install the mounting hardware. Secure the
hardware.
CueSystem Relay Interface
Page 2 of 5
ETC

Advertisement

loading