Flybox Omnia57 ASI-OAT Series Installation And User Manual, Safety Instructions And Warning Booklet

Flybox Omnia57 ASI-OAT Series Installation And User Manual, Safety Instructions And Warning Booklet

Advertisement

Quick Links

FLYBOX
®
®
ASI-OAT
Omnia57-80 ASI-OAT
-
Installation and User Manual,
(Omnia57-80 family)
Safety Instructions and Warning Booklet
1
Rev. 2.0

Advertisement

Table of Contents
loading

Summary of Contents for Flybox Omnia57 ASI-OAT Series

  • Page 1 FLYBOX ® ® ASI-OAT Omnia57-80 ASI-OAT Installation and User Manual, (Omnia57-80 family) Safety Instructions and Warning Booklet Rev. 2.0...
  • Page 2 Installation and User Manual, Safety Instructions and Warning Booklet This product is not TSO’d and cannot be installed into traditional FAA Part 23 and similarly Type-Certificate Aircraft Document A2021ASI-OAT Revision#2.0, 04/2021 For firmware version 1.6 This booklet is suitable for printing in A5 format.
  • Page 3 SECTIONS INTRODUCTION IMPORTANT NOTICE AND WARNINGS INDEX OMNIA FAMILY SYSTEM OVERVIEW MECHANICAL INSTALLATION ELECTRICAL INSTALLATION INSTRUMENT SETTINGS OPERATING INSTRUCTIONS TECHNICAL SPECIFICATIONS WARRANTY DISCLAIMER...
  • Page 4 Examples of available screens...
  • Page 5 FLYBOX ® Introduction Thank you for purchasing a Flybox® Omnia instrument. Omnia instruments are available in 2 different formats, both with the same functionality: Omnia57 (2-1/8") and Omnia80 (3-1/8"). This manual describes both formats. Our intent in developing the Omnia instrument family was to create a light and compact product, powerful and easy to install and use.
  • Page 6 FLYBOX ® Important notices & warnings Symbols used in the Installation and User Manual, Safety Instructions and Warning Booklet NOTE: Used to highlight important information. CAUTION: Used to warn the user, it indicates a potentially hazardous situation or improper use of the product.
  • Page 7 FLYBOX ® Important notices & warnings WARNING: These instructions must be provided to users before use, and retained for ready reference by the user. The user must read, understand (or have explained) and heed all instructions and warnings supplied with this product and with those products intended for use in association with it.
  • Page 8 FLYBOX ® Important notices & warnings WARNING: This device is operated through a software which from time to time can be updated and/or subject to change. Please, always refer to the Installation and User Manual, Safety Instructions and Warning Booklet for the last updated version of the software available at www.flyboxavionics.it...
  • Page 9 Installation and user Manual, Safety Instructions and Warning Booklet, do not install this instrument in his aircraft. NOTE: Flybox Avionics reserves the right to change or improve its products as well as terms, conditions, and notices under which their products are offered without prior notice.
  • Page 10: Table Of Contents

    FLYBOX ® Index INDEX SECTION 1 - Omnia Family System overview…..………… 1.1 - Construction Features …….…………………………..…. 1.2 - Ergonomics………...…...………….……………………. 1.3 - Interconnection Ability ………...…...…………..……….. 1.4 - Easy Software Update ………...…...………….…………. 1.5 - Easy Datalog Saving ………...…...………….…………… 1.6 - Interfaces.. ………...…...………….………………………...
  • Page 11 FLYBOX ® Index 4.3 - Setup Menu Navigation……….…….…..…….………… 4.4 - Main Setup Menu… ………………………….………… 4.4.1 - Gauge Submenu……..…………………….…………… 4.4.2 - ASI Submenu.….….….…….….…………….….……… 23 4.4.3 - OAT Submenu….….…….…….….….….….……….…. 27 4.5 - Backlight Submenu….………….………………………… 28 SECTION 5 - Operating Instructions……….…………………… 31 5.1 - Firmware Upgrade..……………..…..….….…….……….
  • Page 12: Section 1 - Omnia Family System Overview

    FLYBOX ® Omnia Family System Overview OMNIA FAMILY SYSTEM OVERVIEW The Omnia57-80 instrument family has many innovative features, common to all models as described below. 1.1 CONSTRUCTION FEATURES Omnia instrument family is built from solid aluminum alloy, CNC milled and powder coated to last a long time over the years always showing a new appearance.
  • Page 13: Interconnection Ability

    FLYBOX ® Omnia Family System Overview 1.3 INTERCONNECTION ABILITY All the instruments of the Omnia family can be connected together via CAN1 to form a communication network, making some data exchange operations simpler. The software update of a Omnia instrument connected in group takes place through the CAN1 bus communication with the instrument that has the USB pen drive connected.
  • Page 14: Easy Software Update

    1.4 EASY SOFTWARE UPDATE The user can download any new firmware, when available, from Flybox website, connect a USB pen drive to the instrument and freely update it with the last features. With one USB connection only, it will be possible to update every instrument installed in the panel.
  • Page 15: Interfaces

    2 separate CAN BUS: CAN1 bus is used to connect the Omnia instruments together, CAN2 bus is used to interface them with other Flybox instruments or with external devices like Engines ECUs or new devices to be developed in the future.
  • Page 16: Section 2 - Mechanical Installation

    FLYBOX ® Mechanical installation MECHANICAL INSTALLATION It's recommended to choose a position that permits optimal display visibility. The instrument is supplied with four M4 screws to install it to the panel, if you use other screws consider that the maximum thread length inside the instrument body is 10mm (see the picture below).
  • Page 17: Omnia57 Mechanical Dimensions

    FLYBOX ® Mechanical installation 2.1 OMNIA57 MECHANICAL DIMENSIONS The Omnia57 instrument fits in a standard 2 ¼” (57 mm) panel cutout. CAUTION: The maximum screw length inside the instrument body is 10mm. NOTE: For an installation without interference, consider making a hole of at least 57.5 mm diameter.
  • Page 18: Omnia80 Mechanical Dimensions

    FLYBOX ® Mechanical installation 2.2 OMNIA80 MECHANICAL DIMENSIONS The Omnia80 instrument fits in a standard 3 1/8” (80 mm) panel cutout. NOTE: For an installation without interference, consider making a hole of at least 80.5 mm diameter. Omnia57-80 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev.
  • Page 19: Omnia80 Max Screw Lenght

    FLYBOX ® Mechanical installation 2.3 OMNIA80 Max screw length The screws supplied (M4x6mm), are suitable for panel thicknesses between 1.5 mm and 2 mm. Flat nylon washers are also supplied with the screws for use with very thin panels. CAUTION: The maximum screw length inside the instrument body is 3.5mm.
  • Page 20: Static And Pitot Piping Connection

    FLYBOX ® Mechanical installation 2.4 STATIC and PITOT PIPING CONNECTION On the back of the instrument there are 2 6mm brass fittings that must be connected and tightened to the Static and Pitot lines of the aircraft by rubber tube. Tighten the tubes with a proper clamp.
  • Page 21: Section 3 - Electrical Installation

    Molex P/N 43025-0200 (2 pole housing) Molex P/N 43025-2200 (22 pole housing) Molex P/N 43030-0007 (female crimp terminal) The terminals can be crimped with: - Flybox Professional Crimping Tool cod. 603000 - Molex tool P/N 63819-0000 Omnia57-80 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev.
  • Page 22: 22 Pole Female Connector Wiring

    FLYBOX ® Electrical installation 3.2 - (22 POLE) FEMALE CONNECTOR WIRING Lamp or other load 300mA max Blue Green WARNING: Voltage peaks on the supply line exceeding the operating limits can damage the device. Omnia57-80 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev.
  • Page 23: 22 Pole Connector Table

    FLYBOX ® Electrical installation 3.3 - (22 POLE) CONNECTOR TABLE Signal +V Main supply, 10-30Vdc, with a proper breaker, see note1 Vout for sensors, it delivers the same voltage supplied on the Pin 1, short circuit protected and limited to 500mA...
  • Page 24: Sensors Electrical Connections

    FLYBOX ® Electrical installation 3.4 SENSORS ELECTRICAL CONNECTIONS 3.4.1 OAT sensor P1K OAT Sensor Flybox code: 601020 (sold separately) To Omnia57 OAT Input Omnia57-80 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet Rev. 2.0...
  • Page 25: Can Bus Connection Wiring

    Each end must be terminated with a 120 ohm resistor, Flybox code 105810. Up to 16 Omnia can be connected together through CAN 1 bus. Ready-made termination resistors and wiring for connecting several Omnia together are available in different lengths: 25cm, 50cm, 100cm.
  • Page 26: Can Bus Connector Tables

    FLYBOX ® Electrical installation 3.6 - (2 POLE) CAN BUS CONNECTOR TABLES 2 Pole CAN 1 Upper Connector Signal CAN 1 H Internally connected with the Pin 1-CAN 1 H (Lower connector) CAN 1 L Internally connected with the Pin 2-CAN 1 L (Lower connector)
  • Page 27: Section 4 - Instrument Settings

    FLYBOX ® Instrument settings INSTRUMENT SETTINGS 4.1 MINIMUM SETTINGS BEFORE FIRST USE Omnia ASI-OAT CAUTION: Before using the in flight for the first time, you must set at least the following parameters (as explained in the instructions on the following pages): 1.
  • Page 28: Panel Indicators And Commands

    FLYBOX ® Instrument settings 4.2 PANEL INDICATORS & COMMANDS 57mm (2-1/4”) or 80mm (3-1/8”) aluminium enclosure 320X240 pixels, high brightness, readable, color display M4 screws Knob with pushbutton The knob can be rotated to select the functions and increment or decrement the values while pressing it to confirm.
  • Page 29: Setup Menu Navigation

    FLYBOX ® Instrument settings 4.3 SETUP MENU NAVIGATION Navigation through the menus is very simple and fast using the knob: - Press the knob for 1 second to enter in the Setup Menu. The menu automatically disappears if you don’t press or rotate the knob for 5 seconds.
  • Page 30: Main Setup Menu

    FLYBOX ® Instrument settings 4.4 MAIN SETUP MENU Exit: confirm to “exit” from the setup menu and go back to the main screen. Dimmer: adjust display brigtness from 1 (min brightness) to 19 (max brightness). Default value=19. The adjustment works in Manual mode only.
  • Page 31 Exit: confirm to go directly to the main screen. Alarm Tone: choose “Yes” only if the alarm output will be connected to the optional Flybox “Audio Tone Adapter”. This way the output generates a high-pitched tone instead of a continuous signal.
  • Page 32 FLYBOX ® Instrument settings Backlight: set the backlight in “Manual” or “Automatic” mode. Go to chapter 4.5 for a full description. Firmware Upgrade: enter to upgrade the firmware. Go to chapter 5.1 for a full description. Backup/Restore: enter to save and load settings. Go to chapter 5.2 for a full description.
  • Page 33: Gauge Submenu

    FLYBOX ® Instrument settings 4.4.1 Gauges Submenu Back: confirm to go back to previous menu. Exit: confirm to go directly to the main screen. ASI: set the “ASI” parameters. Go to chapter 4.4.2 for a full description. Speed range km/h OAT: set the “OAT”...
  • Page 34: Asi Submenu

    FLYBOX ® Instrument settings 4.4.2 ASI Submenu Back: confirm to go back to previous menu. Exit: confirm to go directly to the main screen. Unit: set the unit of measure of Indicated Air Speed in kilometers per hour (km/h), Knots (kt) or Miles per hour (Mph).
  • Page 35 FLYBOX ® Instrument settings Offset: the ASI indicator sensor is calibrated at the factory at the time of manufacturing. Over the years it may be necessary to do the offset recalibration that can be done by the user in a simple way.
  • Page 36 FLYBOX ® Instrument settings Thresholds: set all the thresholds for the ASI gauge. Rotate the knob to highlight the threshold you want to change, push and change the value, push again to confirm. Default thresholds are at 0. NOTE: Start to change the maximum threshold and then the lower thresholds.
  • Page 37 FLYBOX ® Instrument settings Alarms: enter to go in the Alarm menu. Back: go back to previous menu. Exit: confirm to go directly to the main screen. Overspeed: select to set the high speed at which the alarm has to be triggered. Set this parameter lower than the Vne speed.
  • Page 38: Oat Submenu

    FLYBOX ® Instrument settings 4.4.3 OAT Submenu Back: confirm to go back to previous menu. Exit: confirm to go directly to the main screen. Enable: Unit: set the unit of measure of the Outside Air Temperature in °C or °F.
  • Page 39: Backlight Submenu

    FLYBOX ® Instrument settings 4.5 Backlight Submenu Back: go back to previous menu. Exit: confirm to go directly to the main screen. Mode: select to choose between “Manual” and “Auto”. When in “Manual” mode, the brightness can be changed with the dimmer function from the main menu, from 1 (min brightness) to 19 (max brightness).
  • Page 40 FLYBOX ® Instrument settings Source: choose "Sens" to read the brightness from the optional sensor connected to the instrument itself or "CAN" to read the ambient brightness from the CAN1 bus if the brightness sensor is connected to another Omnia instrument connected in cluster.
  • Page 41 FLYBOX ® Instrument settings Min light(%): choose minimal backlighting when the environment is dark. Default= 1 Min= 1 (dark) Max= 20 (bright) NOTE: if you upgrade to this backlight version for the first time due to a firmware update, the backlight menu items will be reset to their default values.
  • Page 42: Section 5 - Operating Instructions

    FLYBOX ® Operating Instructions OPERATING INSTRUCTIONS 5.1 FIRMWARE UPGRADE The software can be easily updated with new versions, when available. It is advisable to regularly check for new versions on www.flyboxavionics.it > support > software page. Download the new version and after unpacking it, copy it to a USB stick, possibly free from other files.
  • Page 43 FLYBOX ® Operating Instructions If already plugged-in, a message indicating the file and the version will appear: Select and confirm the software you want to write, following screen will appear: In case you are installing a version prior to the...
  • Page 44 FLYBOX ® Operating Instructions Wait until this message will appear and then remove the USB stick. The instrument will reboot with the new software. Note: if the USB stick is installed on a device other than the one you are updating, the following messages will...
  • Page 45: Backup/Restore

    In this case, simply send the backup file saved on the USB stick to the Flybox support service. To backup or restore the parameters it is...
  • Page 46 FLYBOX ® Operating Instructions Select “Backup” and push the knob to write the file on the USB stick. When the file is written, this message will appear: Select “Restore” and push the knob to load the previously saved parameters into the instrument.
  • Page 47: Use Of The Instrument

    FLYBOX ® Operating Instructions 5.3 USE OF THE INSTRUMENT When switched-ON, the display will immediately show the main screen. Speed tape Indicated Air Outside Air Speed Temperature indicator Vx, Vy marks Omnia57-80 ASI-OAT Installation and User Manual, Safety Instructions and Warning Booklet...
  • Page 48: Logger

    FLYBOX ® Operating Instructions 5.4 Logger The Logger can be useful for storing flight data on the USB stick, for example to ask for assistance in case of problems. The data will be stored at 1 second samples and written on a file with some information of the instrument that generated them.
  • Page 49: Technical Specifications

    ● 1 OAT input for PT1000 sensors ● Open-collector alarm output (max 300mA, active low). This output can also be used to send a tone in the intercom, using the Flybox optional device code 105899. ● Operating temperature range: -20 ~ +70°C.
  • Page 50: Warranty

    Products is not intended to be used. Flybox®, after verification of the complaint and confirmation that the defect is covered by warranty, at its sole discretion, will either replace or repair the Products at no costs for the customer.
  • Page 51: Term Of Use And Disclaimer

    FLYBOX ® Disclaimer Term of Use and Disclaimer Limitation of Liability In no event shall MICROEL s.r.l. be liable for any direct, indirect, punitive, incidental, special consequential damages whatsoever arising out of or connected with the use or misuse of its products.
  • Page 52 WARNING: All photos, data, drawings, instruments layouts, technical solutions and data representation you find in this document or watching at FLYBOX® instruments working and/or you can access by means of any other media, including web sites, are sole property of MICROEL s.r.l., cannot be copied or imitate without a written permission of MICROEL s.r.l.
  • Page 53 Flybox® is a registred brand of Microel s.r.l.- Italy www.flyboxavionics.it MICROEL s.r.l. Via Mortara 192-194 27038 Robbio (PV) - ITALY Tel +39-0384-670602 - Fax +39-0384-671830...
  • Page 54 Page Intentionally Left Blank...
  • Page 55 Page Intentionally Left Blank...

This manual is also suitable for:

Omnia80 asi-oat series

Table of Contents