This troubleshooting guide can help you resolve problems related to the Celestron NexStar+ Hand Control. Specifically, if you
have a "No Response" error, "BOOT LOADER" error, or the hand control reports the improper telescope model, follow the
instructions below to see if you can fix the problem on your own.
POSSIBLE PROBLEMS
PROBLEM #1
"No Response" Errors
The hand control displays No Response errors when plugged
into the mount, and the mount is powered on.
• If the hand control displays No Response 16 OR No
Response 17 (only one of these errors and not both), the
problem is with the mount, not the hand control. Contact
Celestron Technical Support at
technical-support
for assistance.
• If the hand control displays BOTH No Response 16 and No
Response 17, the problem could be with either the mount or
the hand control.
• If your mount has an AUX port(s), try plugging the
hand control into the AUX port instead of the HC
(hand control) port. If the No Response error goes
away, there is a problem with your mount's HC
port. You can still use the mount by plugging the
hand control into one of the AUX ports.
• There could be a problem with your power source
providing too low voltage or current. Try using a
different power source to see if the problem goes
away.
• Updating the hand control firmware with Celestron
Firmware Manager may resolve the problem. We'll
explain how in the next section.
• If using the Celestron Focus Motor, and the hand control
displays No Response 18, then there is an issue with the
focus motor not responding or not being detected by the
hand control. If this occurs, try using CFM to update the
hand control firmware to see if this resolves the issue. We'll
explain how to do this in the next section.
• If updating the hand control firmware does not
resolve the No Response 18 error, then there may
be a problem with the focus motor's cable or the
focus motor itself. In this case, please contact
Celestron Technical Support
celestron.com/pages/
for further assistance.
1

Advertisement

loading

Summary of Contents for Celestron NexStar+ Hand Control

  • Page 1 TR O U B LE S H O OTI N G G U I D E This troubleshooting guide can help you resolve problems related to the Celestron NexStar+ Hand Control. Specifically, if you have a “No Response” error, “BOOT LOADER” error, or the hand control reports the improper telescope model, follow the instructions below to see if you can fix the problem on your own.
  • Page 2 In the case where BOOT LOADER appears on the first line of the LCD and “Invalid Package” appears on the second line of the LCD, you will need to reprogram the hand control with the Celestron Firmware Manager. We’ll explain how to do this in the next section.
  • Page 3 Compressed Folder Tools menu at the top of the screen. Visit www.celestron.com/pages/drivers-and-software download CFM. Next, plug your hand control into your Celestron mount as you usually would and power on the mount. The hand control may report errors as described above. Connect your hand control to your computer.
  • Page 4 Open the folder that contains the extracted CFM files and If CFM does not discover the hand control automatically, double click the file called CFM.jar (Windows hides the .jar check your cable connections and press “Seek Devices” in file extension by default). CFM.
  • Page 5 The hand control will display “BOOT LOADER Serial CFM Request” during the update. ©2021 Celestron • All rights reserved • celestron.com 2835 Columbia Street • Torrance, CA 90503 U.S.A. When completed, CFM will report “All your devices are up to 1021 date, ”...