Download Print this page

netvox R718E User Manual page 7

Three-axis digital accelerometer & ntc thermistor
Hide thumbs Also See for R718E:

Advertisement

The accelerometer is a mechanical structure that contains components that can move freely. These moving parts are very sensitive to
mechanical stress, far beyond solid-state electronics. The 0g offset or offset is an important accelerometer indicator because it defines the
baseline used to measure acceleration. After the device is installed, it will be turned on. After 1 minute of network access, the device will
automatically offset the calibration. If the device installation position moves, you need to power off the device after a complete power off for
one minute.
Data report configuration and sending period are as following:
Min Interval
Max Interval
(Unit:second)
(Unit:second)
Any
number
between
Any number between
1~65535
1~65535
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime
S
leeping(MinTime)
Wakes up and collects data
REPORTS 3.6V
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BtteryVoltageChange value.
Example#2
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
S
leeping(MinTime)
0H
15
th
M
Wakes
up
and
Wakes
up
and
collects data
collects data
REPORT 3.6V
3.6V
Does not report
Example#3
based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
sleeping
sleeping
th
0H
15
M
Wakes
up
Wakes up and
and
collects
collects data
data
3.6V Does not
REPORTS
report
3.6V
Reportable
Change
Can not be 0.
Wakes up and collects data
REPORTS 3.5V
MaxTime
sleeping
sleeping
30
th
M
45
Wakes
up
and
Wakes up and collects
collects data
data
3.6V
3.6V
Does not report
Does not report
Wakes up and collects data
3.5V |3.5-3.6|=0.1
REPORTS 3.5V
...
th
th
30
M
45
M
Wakes up and
collects data
3.5V Does not
report
Current
Current
Change≥
Reportable Change
Reportable Change
Report
Report
per Min Interval
per Max Interval
MaxTime
S
leeping(MinTime)
sleeping
th
M
1H
Wakes up and
collects data
REPORTS
3.6V
Users push the button,
REPORTS 3.5V.
Recalculate MaxTime.
th
th
1H
1H 10
M
1H 25
Wakes up and
Wakes up and
collects
collects
data
3.5V Does not
3.5V Does not
report
report
6
Change
Wake up and collects data
REPORTS 3.6V
MaxTime
Wakes up and collects data
3.5V Does not report
th
M
1H 40
M
1H 55
Wakes up and
data
collects data
3.5V Does not
report
2H
th
th
M
2H 10
M
Wakes up and
collects
data
REPORTS 3.5V