8. Technical Performance

8.1 Specifications

Scope
Storage temp.
Ambient temp.
Medium temp.
Power Supply
Current
consumption
Overvoltage
protection
Reverse
protection
Output type
(optional)
Number of
outputs
Switch type
Output load
current
Output voltage
drop
Short circuit
protection
Overload
protection
Switch delay
Electrical
connection
Wetted part
material
(optional)
Operating
pressure
Process
connection
Probe
material/surface
roughness
Enclosure
protection rating
Status indication
Simulation
output test
Standard type
Powder or granular medium
-40°C ~ 85°C (-40°F ~ 185°F)
-40°C ~ 80°C (-40°F ~ 176°F)
40°C~100°C (-40°F~212°F)
12 VDC ~ 30 VDC
Max. 50 mA
Class II
Yes
DC PNP/NPN
2 switch outputs
Group 1 output NO, Group 2 output NC
Max. 50 mA
Max. 2.5 VDC
Short pulse
Yes
Standard < 1 second
M12 4PIN connector socket
SUS316, SUS316L
-1 ~ 40 bar
1/2"G
PEEK/Ra<0.8
IP67
Switch active LED yellow
Switch reset LED green
Magnetic test (lean a magnet close to the + sing for 3 seconds,
there will be switching output)
Rear install type
-40°C ~ 80°C (-40°F ~ 176°F)
3/4"G
9