10. Installation

Before installing and unloading the product, make sure that the device is
not suffered to any pressure and that the material inside the pipe or
container does not have leakage. Pay attention to the potential hazards
relevant to the temperature of the device and the media.

10.1 Installation Environment

Suggested to install the product in a metal container or pipe.
When installed in a plastic container, performance degradation or malfunction
may occur due to interference.
Check that the product is working properly via the field test function.
If interference occurs, take appropriate measures (shielding, grounding).
For pipe installation, the pipe size must be bigger than DN80.
Install the sensor at a distance of at least 30mm from the pipe wall, structural
parts, stirrer, and other sensors to prevent errors caused by collision or
interference (as shown below).
The insertion of the sensor should be sufficient to prevent the sediment from
being wrongly considered as the material. The probe of the sensor must be
completely through the tank wall.
 Do not use seal tape. The sensor must be well grounded with the container
or pipe.
 The sensor probe must be protected from direct sunlight (UV).