10.3 Installation examples

The sensor can be installed as shown below:
Tank Diagram
The figure shows an example of container installation, such as for level
detection or as idling protection.
Note!
1. Mounting the probe at a 20° incline will can avoid material bridges from forming.
It also won't be damaged by the inflowing material.
2. For top-mounted installation, the rear-mounted type with the extension of the
auxiliary rod can be installed at a lower position (◆: the auxiliary rod is not
included in the order).
3. The rear-mounted auxiliary rod extends through the sediment can prevent from
severe bridging. (▼: auxiliary rod is not included in the order)
14