Federal Signal Corporation MicroPulse SignalMaster Manual

Federal Signal Corporation MicroPulse SignalMaster Manual

Advertisement

Quick Links

25500452 Rev A2 0821
Safety Message to Installers and Service Personnel of
Warning Light Equipment
People's lives depend on your proper installation and servicing of Federal Signal products. It is important
to read and follow all instructions shipped with this product and the original product. Listed below are
some other important safety instructions and precautions you should follow:
• To properly install this light, you must have a good understanding of automotive electrical procedures
and systems, along with proficiency in the installation and use of safety warning equipment.
• Always refer to the vehicle's service manuals when performing equipment installations on a vehicle.
• Never attempt to install aftermarket equipment that connects to the vehicle wiring without reviewing
a vehicle wiring diagram available from the vehicle manufacturer. Ensure that your installation will not
affect vehicle operation or mandated safety functions or circuits. Always check the vehicle for proper
operation after installation.
• When drilling into a vehicle structure, ensure that both sides of the surface are clear of anything that
could be damaged.
• In order for the light to function properly, a separate ground connection must be made. If practical, it
should be connected to the fusible link at the front fender between the negative (–) battery terminal
and chassis ground. At a minimum, it may be attached to a solid metal body or chassis part that will
provide an effective ground path as long as the light system is to be used.
• Locate the light control so the VEHICLE and CONTROL can be operated safely under all driving
conditions.
• If a seat is temporarily removed, verify with the vehicle manufacturer if the seat needs to be
recalibrated for proper airbag deployment.
• Do not attempt to activate or deactivate the light control while driving in a hazardous situation.
• This product contains high-intensity LED devices. To prevent permanent eye damage, DO NOT stare
into the light beam at close range.
• Frequently inspect the light system to ensure that it is operating properly and that it is securely
attached to the vehicle.
• Do not install equipment or route wiring in the deployment path of an airbag. Failure to observe this
warning will reduce the effectiveness of the airbag or potentially dislodge the equipment, causing
serious injury to you or others.
• File these instructions in a safe place and refer to them when maintaining and/or reinstalling
the product.
Failure to follow all safety precautions and instructions may result in property damage, serious injury, or
death to you or others.
Instructions for Installing the MicroPulse
SignalMaster
with or Without Brake Module
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MicroPulse SignalMaster and is the answer not in the manual?

Questions and answers

Summary of Contents for Federal Signal Corporation MicroPulse SignalMaster

  • Page 1 Instructions for Installing the MicroPulse ® SignalMaster with or Without Brake Module ™ 25500452 Rev A2 0821 Safety Message to Installers and Service Personnel of Warning Light Equipment People’s lives depend on your proper installation and servicing of Federal Signal products. It is important to read and follow all instructions shipped with this product and the original product.
  • Page 2 ™ Overview The Federal Signal MicroPulse SignalMaster is a directional light assembly for use in a flashing mode. The only lens is clear with red or amber LEDs. The MicroPulse SignalMaster provides these distinctive directional signals: left arrow, right arrow, and center out.
  • Page 3 To remove the light head: 1. Remove and retain the two screws that secure the light to the mounting plate (Figure 1). 2. Disconnect the wire harness connector from the cable assembly. Figure 1 MicroPulse SignalMaster light head removal Faceplate MicroPulse...
  • Page 4 2. Use a mild soap, lukewarm water, and a soft cloth to gently clean the lenses. To avoid damaging the lens, do not use heavy pressure or caustic, abrasive, or petroleum-based cleaners. 3. Rinse and dry the lenses with a soft cloth to prevent water spots. MicroPulse SignalMaster with or Without Brake Module Federal Signal www.fedsig.com...
  • Page 5 Material Authorization (RMA). Obtain an RMA from a local Distributor or Manufacturer’s Representative. Provide a brief explanation of the service requested or the nature of the malfunction. Address all communications and shipments to the following: Federal Signal Corporation MicroPulse SignalMaster with or Without Brake Module Federal Signal www.fedsig.com...
  • Page 6 This product is subject to and covered by a limited warranty, a copy of which can be found at www.fedsig.com/SSG-Warranty. A copy of this limited warranty can also be obtained by written request to Federal Signal Corporation, 2645 Federal Signal Drive, University Park, IL 60484, email to info@fedsig.com or call +1 708-534-3400.
  • Page 7 To order replacement parts, call Customer Support at 1-800-264-3578, 7 a.m. to 5 p.m., Monday through Friday (CT) or contact your nearest distributor. Table 2 Replacement Parts Description Part Number Red, Surface Mount, Brake,12-LED MPS121UD-BRAKE Amber, Surface Mount, 12-LED MPS121UD-A MicroPulse SignalMaster with or Without Brake Module Federal Signal www.fedsig.com...
  • Page 8 2645 Federal Signal Drive University Park, Illinois 60484-3167 www.fedsig.com Customer Support Police/Fire-EMS: 800-264-3578 • +1 708 534-3400 Work Truck: 800-824-0254 • +1 708 534-3400 Technical Support: 800-433-9132 • +1 708 534-3400 © Copyright 2018-2021 Federal Signal Corporation...

This manual is also suitable for:

MicropulseSignalmaster

Table of Contents