4.1 Set Test Configuration........................7 4.2 Set Chart Color ..........................9 5. TEST WINDOW........................... 11 5.1 Test Panel............................11 5.2 Detailed Counter........................... 16 6. DEMO MODE ............................17 7. HOW TO USE LE-580FX QOS ......................17 E-Mail: info@lineeye.co.jp LINEEYE CO.,LTD http://www.lineeye.com...
1. Function Description LE-580FX QoS only runs test in Packet Generation (PG) mode. Choose the target DUT (device under test) or NUT (network under test) and connect two ports (A and B) of LE-580FX to it. Test data is either transmitted from Port A to Port B or from Port B to Port A When both Ports are linked, the LED of PG (used as TAP indicator as well) will be Amber.
<Notice> When you install the LE-580FX QoS, WinPcap Ver4.1.1 will automatically be installed. If you have other version of WinPcap in your PC already, please uninstall it and then install LE-580FX QoS. Setup program indicating LE-580FX QoS will be installed. Click Next for next step.
Page 5
LE-580FX QoS USER'S MANUAL Click Next to begin the installation. This message will appear if you already have WinPcap4.1.1. Click OK. WinPcap installer will start. Click Next. Click Next and start installation of WinPcap. E-Mail: info@lineeye.co.jp LINEEYE CO.,LTD http://www.lineeye.com...
Page 6
Read the License Agreement and click I Agree if you agree with the license. This window will appear when WinPcap installation is finished. Click Finish. Click Close to complete installation. LE-580FX QoS shortcut icon appears on desktop. E-Mail: info@lineeye.co.jp LINEEYE CO.,LTD http://www.lineeye.com...
For Windows Vista, open “Programs and Features” in the Control Panel, choose “LE-580FX QoS” and then click “Uninstall” to uninstall. For Windows XP, open “Add or Remove Programs” in the Control Panel, choose “LE-580FX QoS” and then click “Change/Remove” to uninstall.
Page 8
Shows a window to view detailed statistics of both ports. Options for Help menu are described below: Menu Option Usage About Provide information about the current version of LE-580FX QoS. The buttons in toolbar are described in the table below: Figure Function Opens a saved log file.
LE-580FX QoS USER'S MANUAL 4. Configuration Window 4.1 Set Test Configuration Go to Configuration =>Set Test Configuration to show ” Set Test Configuration Window”. To setup configuration for transmit port, there are Test Direction pane, Test Time pane, Media Type pane, Bandwidth pane, Stream Configuration table, MAC Configuration pane, and Frame Gap pane.
Page 10
LE-580FX QoS USER'S MANUAL Bandwidth between Receive Port and DUT allows receive Port to send pause packets to control bandwidth between itself and DUT in order to diminish/reduce packet losses by choosing available utilization field. It could also demonstrate the priorities of streams in VLAN CoS function.
LE-580FX QoS USER'S MANUAL Frame Gap: Choose desired unit and rate for Frame Gap and then click to setup frame gap for selected streams which you have checked the Enable boxes. Set the speed to transmit packets by clicking button to pop up conversion table of all kinds of units. The same value will be shown in the different units.
Page 12
LE-580FX QoS USER'S MANUAL <Example> Click any pane in “stream 7”. Then the curve will be shown in bold white. Clicks any pane in “stream 2”. Then the curve will be shown in bold orange while the curve of “stream 7” turns into gray.
LE-580FX QoS USER'S MANUAL 5. Test Window 5.1 Test Panel The buttons in Test Panel toolbar are described in the table below: Figure Function/Usage Opens the saved file (*.csv). Saves current log to *.csv file. Starts test. Stops test. Clears counter.
Page 14
LE-580FX QoS USER'S MANUAL Table Port A Tx Packet Rate indicates the number of packets each stream transmits per second. Tx Line Rate is the bandwidth(Mbps) of each stream transmits. Table Port B Rx Packet Rate indicates the number of packets of each stream receives per second. Rx Line Rate indicates the bandwidth of received stream packet.
Page 15
LE-580FX QoS USER'S MANUAL Latency Latency indicates the time of each stream spends transmitting from one port to the other. With higher priority, the faster the stream transmits and the shorter it takes, which makes Latency relatively smaller. The unit of Latency is millisecond. (10...
Page 16
LE-580FX QoS USER'S MANUAL Horizontal Axis Unit of Rx Line Rate Choose between “Real Time” and “Elapsed Time” to determine Horizontal Axis Unit of Rx Line Rate. Horizontal Axis Range The curve chart shows only the latest 60 seconds of the running test as Horizontal Axis Range while test proceeds.
Page 17
Result data is being saved automatically as .csv file to the following directly : C:\Program Files\LINEEYE\LE-580FX\ LE-580FX QoS v1.2b002\Log. In the end, type desired title for the chart and click “save to .csv file” button to save the file as csv format.
LE-580FX QoS USER'S MANUAL 5.2 Detailed Counter This window shows detailed statistics of Port A and B. Click “show detailed counter” button, and open the “Counter Panel” window. Counter Panel Description Link Status status of the port (speed, full/half duplex)
LE580-FX QoS has a Demo Mode. You are able to have the demonstration of LE-580FX QoS. How to use: Open the LE-580FX QoS while not connecting LE-580FX into PC. Click “Yes” when the following window appears. You are able to start the QoS and see the “Test Panel”, “Counter Panel” etc.