IDEAL APP 2300GX Series Assembly Instructions page 2

Ultra short receptacle, receptacle housing

Advertisement

Soldering Method #2, 2300GX Series
Saf-D-Grid Receptacle with contacts sold separately
A 1/8" wide screwdriver tip and Ø.032" lead-free solder is recommended
for use. Solder of 99.2 Sn/0.3 Ag/0.5 Cu composition works well.
Prior to soldering, strip back the wire insulation 0.35" ± 0.01" (8.9 mm ±
0.3 mm). 2016G1-LPBK contacts should be used with 18 AWG wires
only. 2016G2-LPBK contacts should be used with 12 and 10 AWG wires.
The conductors should be looped through the hole in the contact prior to
soldering (Figure 6). Example solder joints are shown in (Figure 7).
Once the contacts have been soldered, they should be inserted into the
receptacle housing (Figure 8). The ground contact should be inserted
into the top position,
wire should be inserted in the position marked with a "L" on the bottom of
the housing. The neutral wire should be inserted in the position marked
with a "N" on the bottom of the housing. Once the contacts have been
inserted, pull slightly to verify they are fully seated past the internal spring.
For demonstration of Soldering Method #1, see the below referenced video on YouTube.
http://youtu.be/Xh64r_LwvWA
TRADEMARKS: "Saf-D-Grid, APP and Anderson Power Products are registered USA and foreign trademarks of Anderson Power Products".
PATENTS: This product is patented. HEADQUARTERS: Anderson Power Products
www.andersonpower.com
All Data Subject To Change Without Notice
Assembly Instructions for AC Saf-D-Grid
perpendicular to the power contacts. The line
Saf-D-Grid
®
Ultra Short Receptacle
®
Page 2
, 13 Pratts Junction Road, Sterling,MA 01564 USA T: 978-422-3600 F:978-422-0128
®
Figure 6
Figure 7
Ground Contact
Figure 8
1S6648
REV 0