Specification
Specification
Type AWT-AC
Refrigerant circuit
Refrigerant
Refrigerant charge
Top-up amount for line lengths >12 m to
≤ 30 m
Compressor (hermetically sealed)
Permiss. operating pressure
■ High pressure side
■ Low pressure side
Integral cylinder
Capacity
Continuous output for DHW heating from
10 to 60 °C
Performance factor N
Max. draw-off rate at the specified perform-
ance factor N
and DHW heating from 10 to
L
45 °C
Max. permissible DHW temperature
External unit dimensions
Total length
Total width
Total height
Internal unit dimensions
Total length
Total width
Total height
Total weight
External unit
Internal unit
Permissible operating pressure, secon-
dary side
144
(cont.)
to DIN 4708
L
221.B10
R 410 A
kg
g/m
Type
Double rotat-
ing piston
bar
MPa
bar
MPa
l
l/h
l/min
°C
mm
mm
mm
mm
mm
mm
kg
kg
bar
MPa
221.B13
R 410 A
2.95
2.95
60
Double rotat-
ing piston
43
4.3
43
4.3
170
170
306
357
1.3
15.9
16.5
95
975
975
340
340
1255
1255
680
680
600
600
1829
1829
113
113
197
197
3
0.3
60
43
4.3
43
4.3
1.4
95
3
0.3